AmberLite FPC88

PDF datasheet mirror for AmberLite FPC88 (DuPont). Verify with OEM before design.

Summary

Product identification

AmberLite™ FPC88 Ion Exchange Resins are macroporous, strong acid cation resins.

Applications

  • Corn and starch sweetener deashing
  • Beet sugar decalcification
  • Citric and lactic acid deashing
  • Fruit juice deashing
  • Beverage demineralization

Typical Properties

Physical Properties

  • Copolymer: Styrene-divinylbenzene
  • Matrix: Macroporous
  • Type: Strong acid cation
  • Functional Group: Sulfonic acid
  • Physical Form: White to yellow, opaque, spherical beads

Chemical Properties

Ionic Form as ShippedTotal Exchange CapacityWater Retention CapacityParticle Size § (< 400 µm)Particle Size § (> 1180 µm)Whole Uncracked BeadsSwelling (Na⁺ → H⁺)Particle DensityShipping Weight
H⁺≥ 1.7 eq/L46 – 56%≤ 5%≤ 5%≥ 95%5%1.2 g/mL770 g/L
Na⁺≥ 1.8 eq/L42 – 48%≤ 5%≤ 5%≥ 95%5%1.2 g/mL800 g/L

§ For additional particle size information, please refer to the Particle Size Distribution Cross Reference Chart (Form No. 45-D00954-en).

Suggested Operating Conditions

  • Maximum Operating Temperature (H⁺ form): 93°C (200°F)
  • pH Range: 0 – 14
  • Bed Depth, min.: 910 mm (3.0 ft)
  • Flowrates:
    • Service: 2 – 4 BV*/h
    • Backwash: See Figure 1
    • Fast Rinse (if applicable): 2 – 10 BV/h
  • Contact Time:
    • Regeneration: ≥30 – 45 minutes
    • Displacement Rinse: ≥30 – 45 minutes
  • Total Rinse Requirement: 3 – 6 BV
  • Regenerant: HCl
    • Concentration: 7%
    • Level, 100% basis ‡: 96 – 112 kg/m³ (6 – 7 lb/ft³)
    • Temperature, max.: 93°C (200°F)

* 1 BV (Bed Volume) = 1 m³ solution per m³ resin or 7.5 gal per ft³ resin ‡ Regeneration level may be lower for counter-current regeneration systems.

Hydraulic Characteristics

Bed expansion of AmberLite™ FPC88 Ion Exchange Resin as a function of backwash flowrate at 25°C (77°F) is shown in Figure 1. The flowrate necessary to achieve a desired bed expansion for other water temperatures can be calculated with the provided equations.

Pressure drop data for AmberLite™ FPC88 as a function of service flowrate and viscosity is shown in Figure 2. These pressure drop expectations are valid at the start of the service run with clean feed.

  • Figure 1: Backwash Expansion
  • Figure 2: Pressure Drop
    • Temperature = 25°C (77°F)
    • Viscosity = 2 – 12 cP
    • For other temperatures use:
      • F<0xE1><0xB5><0x87> = F25°C [1 + 0.008 (1.8T°C −45)], where F ≡m/h
      • F<0xE1><0xB5><0x87> = F77°F [1 + 0.008 (T°F −77)], where F ≡gpm/ft²