Back to DuPont
DuPont logo

Datasheet summary

AmberLite FPX66

PDF datasheet mirror for AmberLite FPX66 (DuPont). Verify with OEM before design.

Summary

Product Identification

  • Product Name: AMBERLITE™ FPX66 Polymeric Adsorbent
  • Description: Macroporous, non-functionalized, adsorbent resin designed for food and biopharmaceutical processing.
  • Type: Adsorbent
  • Copolymer: Crosslinked aromatic polymer
  • Matrix: Macroporous
  • Functional Group: None
  • Physical Form: White, opaque, spherical beads

Applications

  • Food Processing:
    • Decolorization
    • Purification
    • Recovery of high-value materials
  • Biopharmaceutical Processing:
    • Separation of small molecular weight compounds (e.g., antibiotics, vitamins, steroids, amino acids, enzymes, peptides)

Typical Properties

Physical Properties

  • Surface Area (Nitrogen BET): ~700 m²/g
  • Total Pore Volume: ~1.4 cc/g
  • Particle Size:
    • Particle Diameter: 600 – 750 µm
    • Fines (< 300 µm): ≤ 3.0%
    • Oversized (> 1180 µm): ≤ 5.0%
  • Density:
    • Particle Density: 1.015 – 1.025 g/mL
    • Shipping Weight: 680 g/L

Chemical Properties

  • Ionic Form as Shipped: Not applicable
  • Total Exchange Capacity: Not applicable
  • Water Retention Capacity: 60 – 68%
  • DVB Content: ≤ 50 ppb

Suggested Operating Conditions

  • Maximum Operating Temperature: 150°C (302°F)
  • pH Range: 0 – 14
  • Bed Depth, min.: 700 mm (2.3 ft)
  • Flowrates:
    • Loading: 2 – 16 BV*/h (usually)
    • Washing: 1 – 2 BV/h
    • Backwash: See Figure 1 in the original document.
    • Regeneration: 1 – 2 BV/h
    • Rinse: 2 – 16 BV/h
  • Regenerants:
    • Methanol or other water-miscible organic solvents (e.g., ethanol, isopropanol, acetone)
    • Dilute bases and/or dilute acids
    • Hot water or steam for volatile materials

* 1 BV (Bed Volume) = 1 m³ solution per m³ resin or 7.5 gal per ft³ resin.

Hydraulic Characteristics

Estimated bed expansion and pressure drop data are available in the original document's Figures 1 and 2, respectively. These are dependent on flowrate, temperature, and bed condition.

  • Backwash Expansion: Dependent on flowrate and temperature (See Figure 1 in the original document).
  • Pressure Drop: Dependent on service flowrate and temperature (See Figure 2 in the original document).
    • Parameters for Figure 1 (Backwash Expansion): Temperature = 10 – 51.7°C (50 – 125°F)
    • Parameters for Figure 2 (Pressure Drop): Temperature = 4.4 – 65.6°C (40 – 150°F)

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.