AmberLite HPR1200 Na

PDF datasheet mirror for AmberLite HPR1200 Na (DuPont). Verify with OEM before design.

Summary

Product identification

AmberLite™ HPR1200 Na Ion Exchange Resin is a uniform particle size, gel, strong acid cation exchange resin for industrial softening applications. It was previously sold as DOWEX MARATHON™ 1200 Na Ion Exchange Resin.

Applications

  • Industrial softening
  • Demineralization (when the sodium-form is preferred by the user)

System Designs

Compatible with all system technologies including:

  • Co-current
  • Counter-current / Hold-down
  • Packed beds
  • Mixed beds

Typical Properties

Physical Properties

  • Copolymer: Styrene-divinylbenzene
  • Matrix: Gel
  • Type: Strong acid cation
  • Functional Group: Sulfonic acid
  • Physical Form: Dark brown, translucent, spherical beads

Chemical Properties

  • Ionic Form as Shipped: Na⁺
  • Total Exchange Capacity: ≥ 2.0 eq/L (Na⁺ form)
  • Water Retention Capacity: 43.0 – 50.0% (Na⁺ form)

Particle Size

  • Particle Diameter: 585 ± 50 µm
  • Uniformity Coefficient: ≤ 1.10
  • < 300 µm: ≤ 0.1%
  • 850 µm: ≤ 3.0%

Stability

  • Whole Uncracked Beads: ≥ 95%

Swelling

  • Ca²⁺ → Na⁺: 5%
  • Na⁺ → H⁺: 8%

Density

  • Particle Density: 1.29 g/mL
  • Shipping Weight: 820 g/L

Suggested Operating Conditions

  • Temperature Range (Na⁺ form): 5 – 150°C (41 – 302°F)
  • pH Range (Service Cycle): 1 – 14
  • pH Range (Stable): 0 – 14

Hydraulic Characteristics

Estimated bed expansion and pressure drop are provided as a function of backwash flowrate, service flowrate, and temperature. Specific figures and conditions are detailed in the original document.

  • Backwash Expansion (Figure 1): Temperature = 10 – 60°C (50 – 140°F)
  • Pressure Drop (Figure 2): Temperature = 10 – 60°C (50 – 140°F)

Product Stewardship

DuPont is concerned with the safety, health, and environmental aspects of its products. Users are encouraged to review their manufacturing processes and applications to ensure safe and appropriate use. Safety data sheets should be consulted prior to use.

WARNING: Oxidizing agents such as nitric acid can attack organic ion exchange resins, potentially leading to hazardous reactions. Consult knowledgeable sources before using strong oxidizing agents.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.