Datasheet summary
AmberLite HPR252 H
PDF datasheet mirror for AmberLite HPR252 H (DuPont). Verify with OEM before design.
Summary
Product identification
- Product Name: AmberLite™ HPR252 H Ion Exchange Resin
- Type: Uniform Particle Size, Macroporous, Strong Acid Cation Exchange Resin
- Functional Group: Sulfonic acid
- Copolymer: Styrene-divinylbenzene
- Matrix: Macroporous
- Physical Form: Light gray, opaque, spherical beads
- Ionic Form as Shipped: H⁺
- Historical Reference: Previously sold as AmberSep™ 252 H Ion Exchange Resin
Applications
- Mixed bed condensate polishing in fossil power plants
- Single bed industrial demineralization requiring high water purity
- Mixed bed polishing in industrial demineralization
- Systems requiring exceptionally high osmotic stability
Operating Limits
- Temperature Range (H⁺ form): 5 – 150°C (41 – 302°F)
- pH Range (Stable): 0 – 14
Feed Water
Not explicitly specified, but implied for condensate polishing and industrial demineralization.
Product Water
High water purity is implied for demineralization applications.
Typical Properties
- Total Exchange Capacity: ≥ 1.65 eq/L (H⁺ form)
- Water Retention Capacity (H⁺ form): 52.0 – 58.0%
- Ionic Conversion (H⁺ form): ≥ 99%
- Particle Size:
- Particle Diameter: 950 ± 50 µm
- Uniformity Coefficient: ≤ 1.20
- Fines (< 600 µm): ≤ 1.0%
- Oversize (> 1180 µm): ≤ 5.0%
- Stability:
- Whole Uncracked Beads: ≥ 95%
- Swelling (Na⁺ → H⁺): ≤ 7%
- Density:
- Particle Density: 1.19 g/mL
- Shipping Weight: 755 g/L
Mechanical / Hydraulic
- Backwash Expansion: Estimated bed expansion as a function of backwash flowrate and temperature (10 – 60°C / 50 – 140°F) is shown in Figure 1 of the datasheet.
- Pressure Drop: Estimated pressure drop as a function of service flowrate and temperature (10 – 60°C / 50 – 140°F) is shown in Figure 2 of the datasheet. These expectations are valid at the start of the service run with clean water.
Resin Pairings
- Recommended: AmberLite™ HPR900 OH Ion Exchange Resin (macroporous)
- Additional Options: AmberLite™ HPR900 SO4 Ion Exchange Resin (macroporous)
Product Stewardship
DuPont emphasizes product stewardship, focusing on safety, health, and environmental assessment throughout the product lifecycle. Customers are encouraged to review their manufacturing processes and applications to ensure safe and intended use. Safety Data Sheets should be consulted prior to use.
WARNING: Oxidizing agents such as nitric acid can attack organic ion exchange resins, potentially leading to degradation or violent reactions. Consult knowledgeable sources before using strong oxidizing agents.
Disclaimer: Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)