AmberLite IRA910 Cl

PDF datasheet mirror for AmberLite IRA910 Cl (DuPont). Verify with OEM before design.

Summary

Product identification

AmberLite™ IRA910 Cl Ion Exchange Resin is a macroporous, strong base anion (Type II) exchange resin designed for industrial demineralization applications.

Description

This is a general-purpose demineralization resin known for reliable performance in co-flow regenerated industrial water treatment systems. Its macroporous structure offers good resistance to organic fouling and physical stresses, potentially leading to a longer resin lifetime compared to gel Type II resins. Type II resins generally provide greater operating capacity due to more complete regeneration than Type I resins.

This resin is best suited for water where silica and carbon dioxide do not exceed 30% of the total anions, and where service and caustic regeneration temperatures do not consistently exceed 35°C (95°F). For applications requiring low effluent silica or higher operating temperatures, a Type I strong base anion resin, such as AmberLite™ IRA900 Cl, is recommended.

Applications

  • Demineralization in situations with:
    • High organic fouling potential
    • Removal of strong and weak acids
  • Dealkalization

System Designs

  • Co-current regeneration

Typical Properties

Physical Properties

  • Copolymer: Styrene-divinylbenzene
  • Matrix: Macroporous
  • Type: Strong base anion, Type II
  • Functional Group: Dimethylethanolammonium
  • Physical Form: Pale yellow, opaque, spherical beads

Chemical Properties

  • Ionic Form as Shipped: Cl⁻
  • Total Exchange Capacity: ≥ 1.0 eq/L (Cl⁻ form)
  • Water Retention Capacity: 54.0 – 61.0% (Cl⁻ form)
  • Particle Size:
    • Particle Diameter: 530 – 800 µm
    • Uniformity Coefficient: ≤ 1.80
    • Finer than 300 µm: ≤ 2.0%
    • Coarser than 1180 µm: ≤ 5.0%
  • Stability:
    • Whole Uncracked Beads: ≥ 95%
  • Swelling:
    • Cl⁻ → OH⁻: 15%
  • Density:
    • Particle Density: 1.09 g/mL
  • Shipping Weight: 700 g/L

Suggested Operating Conditions

  • Temperature Range:
    • OH⁻ form: 5 – 35°C (41 – 95°F)
    • Cl⁻ form: 5 – 80°C (41 – 176°F)
  • pH Range:
    • Service Cycle: 1 – 14
    • Stable: 0 – 14

Hydraulic Characteristics

Estimated bed expansion during backwash and pressure drop during service are influenced by flow rate and temperature. Refer to the official PDF for detailed figures (Figure 1: Backwash Expansion, Figure 2: Pressure Drop).

Product Stewardship

DuPont emphasizes product stewardship, assessing product safety, health, and environmental information and taking appropriate steps to protect employees, the public, and the environment.

Customer Notice

DuPont recommends customers review their manufacturing processes and applications to ensure products are used as intended. Consult Safety Data Sheets before use.

WARNING: Oxidizing agents like nitric acid can attack ion exchange resins, potentially causing hazardous reactions. Consult knowledgeable sources before using strong oxidizing agents.


Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.