Back to DuPont
DuPont logo

Datasheet summary

AmberLite IRC200 Na

PDF datasheet mirror for AmberLite IRC200 Na (DuPont). Verify with OEM before design.

Summary

Product identification

  • Product Name: AmberLite™ IRC200 Na Ion Exchange Resin
  • Previous Name: AmberLite™ 200C Na Ion Exchange Resin
  • Type: Strong acid cation exchange resin
  • Matrix: Macroporous
  • Copolymer: Styrene-divinylbenzene
  • Functional Group: Sulfonic acid
  • Physical Form: Gray, opaque, spherical beads

Applications

  • Industrial softening, especially when treating water with high oxidant levels or high temperatures.
  • Sodium-cycle or amine-cycle condensate treatment.
  • Hot process softening.
  • System Designs: Co-current

Typical Properties

  • Ionic Form as Shipped: Na⁺
  • Total Exchange Capacity: ≥ 1.8 eq/L (Na⁺ form)
  • Water Retention Capacity: 46.0 – 52.0% (Na⁺ form)

Particle Size

  • Particle Diameter: 600 – 800 µm
  • Uniformity Coefficient: ≤ 1.6
  • Fines (< 300 µm): ≤ 0.5%
  • Oversized (> 1180 µm): ≤ 3.0%

Stability

  • Whole Uncracked Beads: ≥ 98%
  • Swelling (Na⁺ → H⁺): ≤ 6%

Density

  • Particle Density: 1.24 g/mL
  • Shipping Weight: 800 g/L

Suggested Operating Conditions

  • Temperature Range (Na⁺ form): 5 – 150°C (41 – 302°F)
  • pH Range (Service Cycle): 1 – 14
  • pH Range (Stable): 0 – 14

Hydraulic Characteristics

Estimated bed expansion and pressure drop as a function of backwash flowrate, temperature, and service flowrate are illustrated in Figures 1 and 2 respectively. These figures are valid at the start of the service run with clean water and a well-classified bed.

  • Figure 1: Backwash Expansion
    • Temperature: 10 – 60°C (50 – 140°F)
  • Figure 2: Pressure Drop
    • Temperature: 10 – 60°C (50 – 140°F)

Disclaimer: Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.