Summary

Product identification

  • Product Name: AmberLite™ PWA5 Ion Exchange Resin
  • Description: Strongly basic anion exchange resin for selective nitrate removal from drinking water.
  • Copolymer: Styrene-divinylbenzene
  • Matrix: Macroporous
  • Type: Strong base anion
  • Functional Group: Triethylamine
  • Physical Form: Cream, opaque, spherical beads
  • Ionic Form as Shipped: Cl⁻

Applications

  • Primary application: Nitrate removal in potable/drinking water
  • Also can be used for: Selenium removal, Chlorate removal, Perchlorate removal

Chemical Properties

  • Total Exchange Capacity: ≥ 0.9 eq/L
  • Water Retention Capacity: 52 – 58%

Particle Size

  • Particle Diameter: 650 to 850 µm
  • Uniformity Coefficient: ≤ 1.5
  • Fines (< 300 µm): ≤ 0.3%
  • Oversized (> 1180 µm): ≤ 5.0%
  • (For additional particle size information, please refer to the Particle Size Distribution Cross Reference Chart (Form No. 45-D00954-en).)

Physical Properties

  • Density: 690 g/L (Shipping Weight)

Suggested Operating Conditions

  • Maximum Operating Temperature: 40°C (104°F)
  • pH Range (Service Cycle): 5 – 8
  • pH Range (Stable): 0 – 14

Hydraulic Characteristics

Estimated bed expansion and pressure drop data are shown in Figures 1a, 1b, 2a, and 2b, which relate to backwash flowrate and service flowrate as a function of temperature. These pressure drop expectations are valid at the start of the service run with clean water and a well-classified bed.

Conditioning and Limits of Use

AmberLite™ PWA5 Ion Exchange Resin is suitable for use in potable water applications after performing a full regeneration cycle at a dosage of 120 g of NaCl per liter of resin, followed by an adequate rinse to remove excess brine. The operating capacity depends on operating and feedwater conditions. Please confirm the regulatory approval in your specific country of use.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.