Datasheet summary
AmberLyst 17 DRY
PDF datasheet mirror for AmberLyst 17 DRY (DuPont). Verify with OEM before design.
Summary
Product identification
- Product Name: DuPont™ AmberLyst™ 17DRY Polymeric Catalyst
- Product Type: Industrial-grade, Strongly Acidic Catalyst
- Matrix: Macroporous
- Copolymer: Styrene-divinylbenzene
- Functional Group: Sulfonic acid
- Physical Form: White to yellow, opaque, spherical beads
Applications
- Phenol alkylation
- Esterification
- Aldol condensations
- Ester hydrolysis
- Isomerization
- Removal of cationic impurities in non-aqueous ion exchange systems
Physical Properties
- Surface Area (Nitrogen BET): 30 m²/g
- Total Pore Volume: 0.35 cc/g
- Average Pore Diameter: 200 Å
- Shipping Weight: 590 g/L
Chemical Properties
- Ionic Form as Shipped: H⁺
- Concentration of Acid Sites (Dry Weight Capacity): ≥ 4.70 eq/kg
- Catalyst Volatiles: ≤ 3.0%
Particle Size
- Particle Diameter: 475 ± 50 µm
- < 300 µm: ≤ 1.0%
- 400 – 650 µm: ≤ 95.0%
- For additional particle size information: Refer to Particle Size Distribution Cross Reference Chart (Form No. 45-D00954-en).
Swelling
- Phenol: 38%
Suggested Operating Conditions
- Maximum Operating Temperature: 120°C (248°F)
- Bed Depth, min.: 600 mm (2.0 ft)
- Pressure Drop, max.: 1 bar (15 psig) across the bed
- Linear Hourly Space Velocity (LHSV): 0.5 – 5 h⁻¹
Application Information
- The catalyst is produced in a dry form for anhydrous acid-catalyzed reactions.
- For reactions requiring low moisture, drying can be achieved by washing with a dry, water-miscible solvent (alcohol or ketone).
- Exclusion of larger molecules (1500 – 2000 MW) from reaction sites introduces additional selectivity.
Product Stewardship
DuPont's product stewardship philosophy assesses safety, health, and environmental information for products and takes appropriate steps to protect health and the environment.
Customer Notice
DuPont encourages customers to review manufacturing processes and applications to ensure products are not used in ways for which they are not intended or tested. Safety Data Sheets should be consulted prior to use.
WARNING: Oxidizing agents such as nitric acid can attack ion exchange resins under certain conditions, potentially leading to a violent exothermic reaction. Consult knowledgeable sources before using strong oxidizing agents.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.