Datasheet summary
AmberTec UP6040
PDF datasheet mirror for AmberTec UP6040 (DuPont). Verify with OEM before design.
Summary
Product Identification
- Product Name: AmberTec™ UP6040 H/OH Ion Exchange Resin
- Type: Non-Separable, Uniform Particle Size, Mixed Bed Ion Exchange Resin
- Intended Use: Demineralization and ultimate polishing for semiconductor industry
- Previous Name: AMBERJET™ UP6040 Ion Exchange Resin
Description
AmberTec™ UP6040 H/OH is a semiconductor-grade mixed bed ion exchange resin. It is designed for final polishing in high-purity water treatment applications. The product is a pre-mixed combination of strong acid cation and strong base anion ion exchange resins in an equivalent 1:1 ratio. The resin mixture is designed to prevent clumping and separation during handling in water slurry due to its uniform particle size. This ensures optimal performance and allows for high service flow rates, balancing pressure drop and purity for maximum water purity with minimal rinse water.
This product is specifically for non-regenerable final polishing mixed beds in ultrapure water systems, particularly in the semiconductor industry. It is designed to achieve low leakage of ionic species, silica, boron, total organic carbon (TOC), and sub-micron particles. It is not recommended for regenerable mixed bed applications.
Typical Properties
Cation Resin
- Copolymer Matrix: Styrene-divinylbenzene
- Type: Gel, Strong acid cation
- Functional Group: Sulfonic acid
- Physical Form: Dark amber, translucent, spherical beads
- Ionic Form as Shipped: H⁺
- Total Exchange Capacity: ≥ 2.00 eq/L (H⁺ form)
- Water Retention Capacity: 45.0 – 51.0% (H⁺ form)
- Ionic Conversion (H⁺): ≥ 99%
- Particle Size:
- Particle Diameter: 525 ± 50 µm
- Uniformity Coefficient: ≤ 1.20
- < 425 µm: ≤ 0.5%
-
850 µm: ≤ 5.0%
Anion Resin
- Copolymer Matrix: Styrene-divinylbenzene
- Type: Gel, Strong base anion
- Functional Group: Trimethylammonium
- Physical Form: White to yellow, translucent, spherical beads
- Ionic Form as Shipped: OH⁻
- Total Exchange Capacity: ≥ 1.10 eq/L (OH⁻ form)
- Water Retention Capacity: 54.0 – 60.0% (OH⁻ form)
- Ionic Conversion (OH⁻): ≥ 95.0%
- Ionic Conversion (CO₃²⁻): ≤ 5.0%
- Ionic Conversion (Cl⁻): ≤ 0.5%
- Particle Size:
- Particle Diameter: 630 ± 50 µm
- Uniformity Coefficient: ≤ 1.20
- < 425 µm: ≤ 0.5%
-
1180 µm: ≤ 2.0%
Mixed Bed Properties
- Density (Shipping Weight): 710 g/L
Ultrapure Water Performance
- Resistivity at 10-min UPW Rinse: > 17.9 MΩ·cm (‡ based on 18.2-MΩ·cm feedwater)
- Resistivity at 10-min Salt Challenge: > 17.8 MΩ·cm (‡ based on 18.2-MΩ·cm feedwater)
- ΔTOC at 2h00 Rinse: ≤ 3 ppb (C)
Suggested Operating Conditions
- Temperature Range: 15 – 25°C (59 – 77°F) (‡)
- pH Range (Stable): 0 – 14
(‡) Operating at elevated temperatures, for example above 60 – 70°C (140 – 158°F), may impact the purity of the loop and resin life.
Hydraulic Characteristics
Estimated pressure drop as a function of service flowrate and temperature is shown in Figure 1 (see official PDF). These expectations are valid at the start of the service run with clean water.
- Temperature Range for Pressure Drop Estimates: 10 – 60°C (50 – 140°F)
Quality Assurance
AmberTec™ UP6040 H/OH is tested for resistivity, total organic carbon (TOC), and kinetic performance to meet stringent ultrapure water (UPW) requirements. DuPont Water Solutions supports the quality and performance of this product in UPW applications. Typical rinse curves for resistivity and TOC are shown in Figure 2 (see official PDF).
Product Stewardship
DuPont provides information and support to ensure safe handling and use of its products. Customers are encouraged to review manufacturing processes and applications to ensure products are used as intended.
WARNING: Oxidizing agents like nitric acid can attack ion exchange resins, potentially causing degradation or violent reactions. Consult knowledgeable sources before using strong oxidizing agents.