Datasheet summary
AmberChrom CG50
PDF datasheet mirror for AmberChrom CG50 (DuPont). Verify with OEM before design.
Summary
Product identification
- Product Name: AMBERCHROM™ CG50 Chromatography Resin
- Type: Weak acid cation exchange resin
- Matrix: Macroporous
- Copolymer: Crosslinked aromatic polymer
- Functional Group: Carboxylic acid
- Physical Form: White opaque beads
Applications
Isolation and concentration of antibiotics, basic amino acids, enzymes & peptides.
Chemical Properties
- Ionic Form as Shipped: H⁺
- Total Exchange Capacity: 3.9 eq/L
- Water Retention Capacity: 46–55%
Particle Size
- Particle Diameter: 0.400–0.600 mm
- Uniformity Coefficient: < 2
- Oversize (> 1180 µm): 5.0% max
- Undersize (< 350 µm): 20% max
Suggested Operating Conditions
- Minimum Bed Depth: 600 mm
- Flowrate: 3 – 30 BV/h*
Regenerant: HCl
- Concentration: 2 – 5%
- Level: 105% of the ionic load
- Minimum contact time: ≥ 30 minutes
Regenerant: H₂SO₄
- Concentration: 0.5 – 0.7%
- Level: 105% of the ionic load
- Minimum contact time: ≥ 30 minutes
Hydraulic Characteristics
- Figures 4 and 5 in the original document show bed expansion and pressure drop data, respectively, as functions of flow rate and water temperature. These figures are valid at the start of the service run with clear water and a correctly classified bed.
Disclaimer
The extracted information may not include all figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.