Datasheet summary
LEWATIT® A 8075 KR
PDF datasheet mirror for LEWATIT® A 8075 KR (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
Lewatit® A 8075 KR is a weakly basic, gel type anion exchange resin based on an acrylic copolymer with a special bead size distribution. It has a porous polyacrylate structure, offering high capacities and kinetic properties.
Applications
- Treatment of radioactive waste after full system decontamination
- Clean-up of radioactive waste
- Applications in nuclear power stations
Physical and Chemical Properties
- Ionic form as shipped: Free base
- Functional group: Polyamine
- Matrix: Crosslinked polyacrylate
- Structure: Gel
- Appearance: Yellow-white, opaque
- Uniformity Coefficient: max. 1.8
- Effective size: 0.50 (+/- 0.05) mm
- Bulk density: 730 (+/- 5 %) g/l
- Density: approx. 1.13 g/ml
- Water retention: 44 - 51 wt. %
- Total capacity: min. 3.5 eq/l
- Volume change (free base --> Cl⁻): max. 16 vol. %
- Stability (pH-range): 0 - 14
- Storability (product): max. 2 years
- Storability (temperature range): -20 to +30 °C
Recommended Operating Conditions
- Operating temperature: max. 70 °C
- Operating pH-range: 0 - 9
- Bed depth: min. 800 mm
- Specific pressure drop (15 °C): approx. 1.1 kPa*h/m²
- Pressure loss: max. 150 kPa
- Linear velocity (operation): 5 - 40 m/h
- Linear velocity (backwash, 20 °C): approx. 9 m/h
- Bed expansion (20 °C, per m/h): approx. 15 vol. %
- Freeboard (backwash, external / intern): 80 - 100 vol. %
Regeneration
- Regenerant: NaOH
- Regeneration level (counter current): approx. 64 - 128 g/l
- Concentration (WS-System): approx. 3 - 5 wt. %
- Linear velocity (regeneration): approx. 5 m/h
- Linear velocity (rinsing): approx. 5 m/h
- Rinse water requirement (slow / fast): approx. 1 - 3 / 3 - 8 BV
Additional Information
- Safety precautions: Avoid contact with strong oxidants like nitric acid. Refer to the safety data sheet for detailed information on handling, storage, transport, safety, and ecology.
- Disposal: Dispose of in accordance with the European waste nomenclature.
- Storage: Store above freezing point, dry, and out of direct sunlight. If frozen, allow to thaw gradually at ambient temperature before handling or use.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.