LEWATIT® CNP 80 WS
PDF datasheet mirror for LEWATIT® CNP 80 WS (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
- Product Name: LEWATIT® CNP 80 WS
- Common Description: Weakly acidic, macroporous, acrylic-based cation exchange resin of standard bead size distribution.
- Functional group: Carboxylic acid
- Matrix: Crosslinked polyacrylate
- Structure: Macroporous
- Delivery form: H⁺
- Appearance: Yellow, white
Applications
- Dealkalisation of industrial water by co-current systems.
- In combination with a strong acidic cation exchange resin (e.g., Lewatit® MonoPlus S 108) in the decationization step of water demineralization.
- Removal of temporary hardness (hardness associated with alkalinity).
- Single bed polisher downstream of a demineralization unit for removal of cations present as hydroxides at high flow rates.
- Produced water softening as a single filter unit or in combination with Lewatit® S 1567 as a polisher.
- In its sodium-form for the removal/extraction of heavy metals (e.g., copper, nickel, zinc) from electroplating rinse waters at pH > 5 in the absence of calcium and complexing agents.
Specified Data
- Uniformity coefficient: max. 1.8
- Range of size for >90% vol of all beads: 0.4 - 1.6 mm
- Effective size (d10): 0.48 - 0.58 mm
- Total capacity (delivery form): min. 4.5 eq/L
Typical Physical and Chemical Properties
- Bulk density for shipment (+/- 5%): 750 g/L
- Density: approx. 1.19 g/mL
- Water retention (delivery form): approx. 42 - 47 % weight
- Volume change (H⁺ to Ca²⁺): max. approx. 7 %
- Volume change (H⁺ to Na⁺): max. approx. 70 %
- Stability pH range: 0 - 14
- Storage time (after delivery): max. 2 years
- Storage temperature range: -20 - +40 °C
Operation
- Operating temperature: max. 95 °C
- Operating pH range during exhaustion: 5 - 14
- Bed depth for single column: min. 800 mm
- Backwash bed expansion per m/h (20°C): 4 %
- Specific pressure loss (15°C): 1.3 kPa*h/m²
- Max. pressure loss during operation: 250 kPa
- Specific flow rate: max. 40 BV/h
Regeneration
- HCl regeneration concentration: approx. 3 - 6 wt. %
- HCl regeneration quantity (co-current): min. 70 g/L resin
- H₂SO₄ regeneration concentration: approx. 0.5 - 0.8 wt. %
- H₂SO₄ regeneration quantity (co-current): min. 90 g/L resin
- Regeneration contact time: min. 20 minutes
- Slow rinse at regeneration flow rate: 2 BV
- Fast rinse at service flow rate: 2 BV
Additional Information & Regulations
- Safety precautions: Strong oxidants (e.g., nitric acid) can cause violent reactions. Observe the safety data sheet.
- Storage: Recommended to store above freezing point, dry, under roof, out of direct sunlight. If frozen, thaw gradually at ambient temperature.
- Packaging stability: Limited to 24 months under recommended storage conditions.