Datasheet summary
LEWATIT® CNP C
PDF datasheet mirror for LEWATIT® CNP C (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
- Product Name: Lewatit® CNP C
- Product Type: Macroporous, weakly acidic cation exchange resin
- Matrix: Crosslinked polyacrylate
- Functional group: Carboxylic acid
- Delivery form: H⁺
- Appearance: White, opaque beads
Operating limits
- pH range: 0 - 14
- Temperature range: -20 to +70 °C
- Storage temperature: -20 to +40 °C
- Storability: max. 1 year
Feed water
- Application: Decarbonisation and softening of drinking water (e.g., brewery water treatment), household filter systems.
- Note: Special care required for initial cycles when treating potable water. Recommended start-up conditions available on request. For potable water treatment in France, regeneration must use HCl or H₂SO₄ solutions, and disinfection must use H₂O₂ solutions, complying with specific purity norms (NF EN 939 for HCl, NF EN 899 for H₂SO₄, NF EN 902 for H₂O₂).
Product water
- Application: Decarbonisation and softening of drinking water and liquids used as foodstuffs or in foodstuff production.
Electrical
No information available in the extract.
Mechanical / hydraulic
- Uniformity coefficient: max. 1.8
- Effective bead size: 480 (+/- 5) microns
- Range of size for > 90% of beads: 400 - 1600 microns
- Water retention: 52 - 58 wt. %
- Total capacity: min. 4.0 eq/L (H⁺ form)
- Bulk density: approx. 770 g/L (+/- 5%)
- Density: approx. 1.17 g/mL
- Volume change (H⁺ → Na⁺): max. 64 vol. %
- Volume change (H⁺ → Ca²⁺): max. 7 vol. %
- Pressure drop: max. 250 kPa
- Specific pressure drop (at 15°C): approx. 1.3 kPa*h/m²
- Bed expansion (at 20°C, per m/h): 5 vol. %
Operation & Regeneration (Recommended)
- Operating temperature: max. 70 °C
- Operating pH-range: 5 - 14
- Bed depth: min. 800 mm
Regeneration, Counter-current
- Regenerant Type: HCl or H₂SO₄
- Regenerant Quantity: HCl approx. 70 g/L; H₂SO₄ approx. 90 g/L
- Regenerant Concentration: HCl 3 - 6 wt. %; H₂SO₄ 0.5 - 0.8 wt. %
- Linear velocity (Regeneration): approx. 5 - 20 m/h
- Linear velocity (Rinsing): approx. 5 - 20 m/h
- Rinse water requirement (slow/fast): approx. 3.5 BV
Regeneration, Co-current
- Regenerant Type: HCl or H₂SO₄
- Regenerant Quantity: HCl approx. 120 g/L; H₂SO₄ approx. 150 g/L
- Regenerant Concentration: HCl approx. 3 - 6 wt. %; H₂SO₄ approx. 0.5 - 0.8 wt. %
- Linear velocity (Backwash at 20°C): approx. 12 - 14 m/h
- Linear velocity (Rinsing): approx. 5 - 20 m/h
- Freeboard (Backwash, external/internal): 60 - 80 vol. %