Back to Lanxess LEWATIT
Lanxess logo

Datasheet summary

LEWATIT® K 6362

PDF datasheet mirror for LEWATIT® K 6362 (Lanxess LEWATIT). Verify with OEM before design.

Summary

Product identification

Lewatit® K 6362 is a strongly basic (type I), gel-type ion exchange resin. It is based on a styrene-divinylbenzene copolymer with a very narrow bead size distribution (monodisperse grade).

Common Description:

  • Delivery form: Cl⁻
  • Functional group: Quaternary ammonium salt, type 1
  • Matrix: Styrenic
  • Structure: Gel
  • Appearance: Light yellow, translucent

Applications

In its delivered chloride (Cl⁻) form, Lewatit® K 6362 can be used for:

  • Recovery of precious metal cyano and chloro complexes from waste water or process streams.
  • Removal of anionic heavy metal complexes from hydrochloric acid.
  • Recovery of uranium from both carbonate and sulfuric acid leach solutions.

In its hydroxide (OH⁻) form, Lewatit® K 6362 is particularly suitable for:

  • The removal of mercaptane sulfur from hydrocarbon streams.
  • Catalysis of organic reactions of small polar molecules in the temperature range from 30 to 60 °C.

Operating limits

  • Stability pH range: 0-14
  • Storage temperature range: -20 - +40 °C
  • Operating temperature (max.): 70 °C
  • Operating pH range during exhaustion: 0-12
  • Bed depth for single column (min.): 1000 mm
  • Backwash bed expansion (per m/h at 20°C): 11 %
  • Max. pressure loss during operation: 250 kPa

Feed water

  • Specific pressure loss: 1.0 kPa*h/m² (at 15°C)

Product water

  • Total capacity (delivery form): min. 1.3 eq/L

Electrical

N/A

Mechanical / hydraulic

  • Uniformity coefficient (max.): 1.1
  • Mean bead size (d₅₀): 0.62 (±0.05) mm
  • Bulk density for shipment (±5%): 690 g/L
  • Density (approx.): 1.08 g/mL
  • Water retention (delivery form) (approx.): 48-55 % weight
  • Volume change (Cl⁻ - OH⁻) (max. approx.): 22 %

Additional Information

  • Storage: Recommended to store at temperatures above freezing, under roof, in dry conditions, away from direct sunlight. Frozen resin should thaw gradually at ambient temperature.
  • Packaging stability: Limited to 24 months under recommended storage conditions.
  • Safety: Avoid contact with strong oxidants (e.g., nitric acid). Refer to the safety data sheet.
  • Disposal: According to European waste nomenclature.

Disclaimer: This extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.