Datasheet summary
LEWATIT® K 6367
PDF datasheet mirror for LEWATIT® K 6367 (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
- Product Name: Lewatit® K 6367
- Common Description: Strongly basic, gel-type resin (type-1)
- Functional group: Quaternary ammonium, type 1
- Matrix: Styrenic
- Structure: Gel
- Appearance: Light yellow, translucent
- Delivery form: Cl⁻
Operating limits
- Stability pH range: 0-14
- Stability temperature range: 1-70 °C
- Operating temperature: max. 70 °C
- Operating pH range during exhaustion: 0-12
- Max. pressure loss during operation: 250 kPa
Feed water / Applications
- Removal of precious metal cyano and chloro complexes from wastewater or process streams.
- Removal of anionic heavy metal complexes from hydrochloric acid.
- Recovery of uranium from both carbonate as well as acid leach solutions, especially in fluidized bed (e.g. NIMCIX columns) and fixed bed systems.
Product Water / Resin Properties
- Total capacity (delivery form): min. 1.2 eq/L
- Uniformity coefficient: max. 1.2
- Mean bead size (d₅₀): 0.92 (±0.05) mm
- Water retention (delivery form): 49-54 % by weight
- Volume change (Cl⁻ - OH⁻): max. approx. 20 %
Electrical
None specified.
Mechanical / Hydraulic
- Bulk density for shipment (±5%): 630 g/L
- Bed depth for single column: min. 1000 mm
Storage and Handling
- Storage temperature range: -20 - +40 °C
- Recommended storage: Above freezing point of water, under roof in dry conditions, without direct sunlight.
- Packaging stability: Limited to 24 months under recommended storage conditions.
- Safety precautions: Strong oxidants (e.g., nitric acid) can cause violent reactions. Consult the safety data sheet.
- Disposal: According to European waste nomenclature within the European Community.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)