Back to Lanxess LEWATIT
Lanxess logo

Datasheet summary

LEWATIT® K 6387

PDF datasheet mirror for LEWATIT® K 6387 (Lanxess LEWATIT). Verify with OEM before design.

Summary

Product identification

Lewatit® K 6387 is a strongly basic, bead-shaped, monodisperse, gelular type-I anion exchange resin based on a styrene-divinylbenzene copolymer. It is specially suitable for:

  • Lifetime extension of acid baths (acid retardation process)
  • Chromatographic separation and ion exclusion processes
  • Demineralization (in hydroxide form) of water and aqueous solutions

Physical and Chemical Properties

  • Ionic form as shipped: Cl⁻
  • Functional group: quaternary amine, type I
  • Matrix: crosslinked polystyrene
  • Structure: gel type beads
  • Appearance: yellow, translucent
  • Uniformity Coefficient: max. 1.1
  • Mean bead size: 0.3 mm (± 0.05)
  • Bulk density: 700 g/l (± 5 %)
  • Density: approx. 1.10 g/ml
  • Water retention: 48 - 55 wt. %
  • Total capacity: min. 1.5 eq/l
  • Volume change (Cl⁻ --> OH⁻): max. 25 vol. %
  • Stability (pH-range): 0 - 14
  • Storability (max years): 2
  • Storability temperature range: -20 - 70 °C

Recommended Operating Conditions

  • Operating temperature:
    • OH⁻ form: max. 70 °C
    • Cl⁻ form: max. 90 °C
  • Operating pH-range: 0 - 12
  • Bed depth (min.): 800 mm
  • Specific pressure drop (15 °C): approx. 2.8 kPa·h/m²
  • Pressure drop (max.): 200 kPa
  • Linear velocity (operation):
    • Water: 5 - 40 m/h
    • Sugar: 1 - 5 m/h
  • Linear velocity (backwash, 20 °C): approx. 7 - 9 m/h
  • Bed expansion (20 °C, per m/h): approx. 25 vol. %
  • Freeboard (backwash, external / internal): 80 - 100 vol. %

Regeneration

  • Regenerant: NaOH or NaCl + NaOH
  • Regeneration level (approx. g/l):
    • NaOH: 50 - 80
    • NaCl + NaOH: 20
  • Concentration (approx. wt. %):
    • NaOH: 4 - 10 %
    • NaCl + NaOH: 1 - 2 %
  • Linear velocity (regeneration): approx. 5 m/h
  • Linear velocity (rinsing): approx. 5 m/h
  • Rinse water requirement (slow / fast): approx. 4 BV

Additional Information & Regulations

  • Safety precautions: Strong oxidants (e.g., nitric acid) can cause violent reactions. Observe the safety data sheet.
  • Disposal: Dispose of according to European waste nomenclature.
  • Storage: Store above freezing point, under roof, dry, out of direct sunlight. If frozen, thaw gradually at ambient temperature.