Back to Lanxess LEWATIT
Lanxess logo

Datasheet summary

LEWATIT® MonoPlus M 500

PDF datasheet mirror for LEWATIT® MonoPlus M 500 (Lanxess LEWATIT). Verify with OEM before design.

Summary

Product identification

  • Product name: Lewatit® MonoPlus M 500
  • Type: Strongly basic, gelular anion exchange resin
  • Bead type: Uniform size (monodisperse)
  • Matrix: Styrene-divinylbenzene copolymer
  • Functional group: Quaternary ammonium, Type 1
  • Common description: Cl⁻
  • Delivery form: Gel
  • Appearance: Yellow, translucent

Applications

  • Demineralization of water for industrial steam generation (e.g., Lewatit® WS System, Lewatit® Liftbed System, Lewatit® Rinsebed System)
  • Polishing in combination with Lewatit® MonoPlus S 108 H in a Lewatit® Multistep System

Key Features

  • High exchange flow rates during regeneration and loading
  • Good utilization of total capacity
  • Low demand for rinse water
  • Homogenous throughput of regenerants, water, and solutions, resulting in a homogenous working zone
  • Nearly linear pressure drop gradient, allowing for higher bed depth operation

Specified Data

  • Uniformity coefficient: max. 1.1
  • Mean bead size (d₅₀): 0.62 (±0.05) mm
  • Total capacity (delivery form): min. 1.3 eq/L

Typical Physical and Chemical Properties

  • Bulk density (for shipment): 690 g/L (±5%)
  • Density: approx. 1.08 g/mL
  • Water retention (delivery form): approx. 48 - 55 % (by weight)
  • Volume change (Cl⁻ to OH⁻): max. approx. 24 %
  • Stability pH range: 0 - 14
  • Storage time (after delivery): max. 2 years
  • Storage temperature range: -20 - +40 °C

Operation

  • Operating temperature: max. 70 °C
  • Operating pH range (during exhaustion): 0 - 12
  • Bed depth (single column): min. 800 mm
  • Backwash bed expansion (per m/h at 20°C): 11 %
  • Specific pressure loss (at 15°C): 1 kPa*h/m²
  • Max. pressure loss (during operation): 200 kPa
  • Specific flow rate: max. 60 BV/h

Regeneration

  • Regeneration chemical: NaOH
  • NaOH regeneration concentration: approx. 2 - 6 wt. %
  • NaOH regeneration quantity (co-current): min. 80 g/L resin
  • NaOH regeneration quantity (counter-current): min. 50 g/L resin
  • Regeneration contact time: min. 20 minutes
  • Slow rinse (at regeneration flow rate): min. 2 BV
  • Fast rinse (at service flow rate): min. 2 BV

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.