Datasheet summary
LEWATIT® MonoPlus M 500 OH
PDF datasheet mirror for LEWATIT® MonoPlus M 500 OH (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
- Product Name: Lewatit® MonoPlus MP 500 OH
- Description: Strongly basic, macroporous anion exchange resin (Type I) with uniform size beads (monodisperse) based on a styrene-divinylbenzene copolymer.
- Edition: 2020-11-26
Applications
- Polishing using the Lewatit® Multistep System or a conventional mixed bed arrangement in combination with Lewatit® MonoPlus SP 112 H or Lewatit® MonoPlus S 108 H.
- Condensate polishing in combination with Lewatit® MonoPlus SP 112 H or Lewatit® MonoPlus S 200 KR.
- Demineralization of water for industrial steam generation in co-current or counter-current systems (e.g., Lewatit® WS System, Lewatit® Liftbed System, Lewatit® Rinsebed System).
Resin Bed Features
- High flow rates during regeneration and loading.
- Good utilization of total capacity.
- Low rinse water requirement.
- Homogeneous throughput of regenerants, water, and solutions.
- Virtually linear pressure drop gradient.
- Good separation of components in mixed bed applications.
Specified Data
- Common Description: OH⁻
- Functional Group: Quaternary ammonium Type 1
- Matrix: Styrenic
- Structure: Macroporous
- Appearance: Beige, opaque
- Uniformity coefficient: max. 1.1
- Mean bead size (d₅₀): 0.65 (±0.05) mm
- Total capacity (delivery form): min. 0.9 eq/L
Typical Physical and Chemical Properties
- Bulk density for shipment (±5%): 620 g/L
- Density: approx. 1.06 g/mL
- Water retention (delivery form): approx. 70-77 % by weight
- Volume change (OH⁻ ➔ Cl⁻): max. approx. -22 %
- Stability pH range: 0-14
- Storage time (after delivery): max. 1 year
- Storage temperature range: -20 to +40 °C
- Ionic conversion OH⁻: min. 80 % eq.
Operating Parameters
- Operating temperature: max. 70 °C
- Operating pH range during exhaustion: 0-12
- Bed depth for single column: min. 800 mm
- Bed depth per component in mixed bed: min. 500 mm
- Backwash bed expansion per m/h (20°C): 18 %
- Specific pressure loss (15°C): 0.8 kPa*h/m²
- Max. pressure loss during operation: 300 kPa
- Specific flow rate: max. 100 BV/h
Regeneration Parameters
- NaOH regeneration concentration: approx. 2-6 wt. %
- NaOH regeneration quantity (co-current): min. 100 g/L resin
- NaOH regeneration quantity (counter-current): min. 50 g/L resin
- Regeneration contact time: min. 20 minutes
- Slow rinse at regeneration flow rate: min. 2 BV
- Fast rinse at service flow rate: min. 2 BV
Safety and Storage
- Contact with strong oxidants (e.g., nitric acid) can cause violent reactions.
- Observe the Safety Data Sheet for detailed information on transport, storage, handling, safety, and ecology.
- Dispose of ion exchange resins according to European waste nomenclature.
- Recommended storage: above freezing point, dry, under roof, out of direct sunlight.
- If frozen, thaw gradually at ambient temperature; do not mechanically handle until completely thawed.
- Packaging stability is limited to 24 months under recommended storage conditions; check packaging condition regularly if used beyond this period.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.