LEWATIT® MonoPlus MP 800
PDF datasheet mirror for LEWATIT® MonoPlus MP 800 (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
Lewatit® MonoPlus MP 800 is a strongly basic, macroporous anion exchange resin (type I) with beads of uniform size (monodisperse) based on a styrene-divinylbenzene copolymer, designed for all demineralization applications.
Key Features
- High flow rates during regeneration and loading
- Good utilization of the total capacity
- Low rinse water requirement
- Homogeneous throughput of regenerants, water and solutions, resulting in a homogeneous operating zone
- Virtually linear pressure drop gradient across the entire bed depth, allowing operation with higher bed depths
- Good separation of the components in mixed bed applications
- Effective adsorption and desorption of naturally occurring organic substances
Applications
- Demineralization of water for industrial steam generation (e.g., Lewatit® WS System, Lewatit® Liftbed System, Lewatit® Rinsebed System)
- Polishing using the Lewatit® Multistep System or a conventional mixed bed arrangement in combination with Lewatit® MonoPlus SP 112 (H)
- Condensate polishing in combination with Lewatit® MonoPlus SP 112 (H)
Specified Data
- Common Description
- Delivery form: Cl⁻
- Functional group: Quaternary ammonium, Type 1
- Matrix: Styrenic
- Structure: Macroporous
- Appearance: Beige, opaque
- Specified Data
- Uniformity coefficient: max. 1.1
- Mean bead size (d₅₀): 0.62 (±0.05) mm
- Total capacity (delivery form): min. 1.0 eq/L
Typical Physical and Chemical Properties
- Bulk density for shipment (±5%): approx. 620 g/L
- Density: approx. 1.06 g/mL
- Water retention (delivery form): approx. 63-68 % by weight
- Volume change (Cl⁻ - OH⁻): max. approx. 22 %
- Stability pH range: 0-14
- Storage time (after delivery): max. 2 years
- Storage temperature range: -20 to +40 °C
Operating Parameters
- Operating temperature: max. 70 °C
- Operating pH range during exhaustion: 0-12
- Bed depth for single column: min. 800 mm
- Bed depth per component in mixed bed: min. 500 mm
- Backwash bed expansion per m/h (20°C): 19 %
- Specific pressure loss (15°C): 0.8 kPa*h/m²
- Max. pressure loss during operation: 300 kPa
- Specific flow rate: max. 100 BV/h
Regeneration Parameters
- NaOH regeneration concentration: approx. 2-6 wt.%
- NaOH regeneration quantity (co-current): min. 80 g/L resin
- NaOH regeneration quantity (counter-current): min. 50 g/L resin
- Regeneration contact time: min. 20 minutes
- Slow rinse at regeneration flow rate: min. 2 BV
- Fast rinse at service flow rate: min. 2 BV
Additional Information & Regulations
- Safety precautions: Strong oxidants, e.g., nitric acid, can cause violent reactions if they come into contact with ion exchange resins.
- Toxicity: The safety data sheet must be observed.
- Disposal: Ion exchange resins must be disposed of according to the European waste nomenclature within the European Community.
- Storage: Recommended to store at temperatures above the freezing point of water, under roof, in dry conditions, and without direct sunlight. If frozen, allow to thaw gradually at ambient temperature before handling or use.
- Packaging: Packaging stability is limited to 24 months under recommended storage conditions. It is recommended to use the product within this timeframe or to check packaging condition regularly.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.