Datasheet summary
LEWATIT® S 200 H
PDF datasheet mirror for LEWATIT® S 200 H (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
- Product name: Lewatit® MonoPlus S 200 H
- Edition: 2017-11-23
- Common Description: H⁺
- Functional group: Sulfonic acid
- Matrix: Styrenic
- Structure: Gel
- Appearance: Dark brown
Applications
Lewatit® MonoPlus S 200 H is especially suitable for:
- Demineralization of water for industrial steam generation (co-current or modern counter-current systems like Lewatit WS System, Lewatit Liftbed System or Lewatit Rinsebed System).
- Polishing using the Lewatit Multistep System or a conventional mixed bed.
- Arrangements in combination with anion components: Lewatit® MonoPlus M 800 and Lewatit® MonoPlus M 800 OH.
The resin adds special features to the resin bed:
- High flow rates during regeneration and loading.
- High operating capacity at low regenerant consumption.
- Low rinse water requirement.
- Homogeneous throughput of regenerants, water and solutions.
- Low TOC emission and high resistance to oxidative stress.
- Good separation of components in mixed bed applications.
Specified Data
- Uniformity coefficient: max. 1.1
- Mean bead size (d₅₀): 0.60 (+-0.05) mm
- Total capacity (delivery form): min. 2.1 eq/L
Typical Physical and Chemical Properties
- Bulk density for shipment (+/- 5%): 790 g/L
- Density (approx.): 1.23 g/mL
- Water retention (delivery form, approx. weight %): 45-50 %
- Volume change (H⁺ - Na⁺, max. approx. %): -8 %
- Stability pH range: 0-14
- Storage time (after delivery, max.): 1 year
- Storage temperature range: -20 - +40 °C
- Ionic conversion H⁺ (min. eq. %): 99.9 %
Operation
- Operating temperature (max.): 140 °C
- Operating pH range during exhaustion: 2-14
- Bed depth for single column (min.): 800 mm
- Bed depth per component in mixed bed (min.): 500 mm
- Backwash bed expansion per m/h (20°C): 3.5 %
- Specific pressure loss (15°C): 1 kPa*h/m²
- Max. pressure loss during operation: 250 kPa
- Specific flow rate (max.): 100 BV/h
Regeneration
HCl Regeneration
- Concentration (approx. wt. %): 4-6 %
- Quantity co-current (min.): 100 g/L resin
- Quantity counter-current (min.): 55 g/L resin
H₂SO₄ Regeneration
- Concentration (approx. wt. %): 1.5-8 %
- Quantity co-current (min.): 120 g/L resin
- Quantity counter-current (min.): 80 g/L resin
Rinsing
- Regeneration contact time (min.): 20 minutes
- Slow rinse at regeneration flow rate: 2 BV
- Fast rinse at service flow rate: 2 BV
Additional Information
- Safety precautions: Strong oxidants, e.g., nitric acid, can cause violent reactions if they come into contact with ion exchange resins.
- Toxicity: The safety data sheet must be observed.
- Disposal: Ion exchange resins in the European Community must be disposed of according to the European waste nomenclature.
- Storage: Store under roof in dry conditions, without direct sunlight, and above the freezing point of water. If frozen, thaw gradually at ambient temperature.
- Packaging: Packaging stability is limited to 24 months under recommended storage conditions.
Disclaimer: This extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.