Back to Lanxess LEWATIT
Lanxess logo

Datasheet summary

LEWATIT® MonoPlus TP 207 XL

PDF datasheet mirror for LEWATIT® MonoPlus TP 207 XL (Lanxess LEWATIT). Verify with OEM before design.

Summary

Product identification

Lewatit® MonoPlus TP 207 XL is a weakly acidic, macroporous cation exchange resin with chelating iminodiacetate groups. It is designed for the selective extraction of heavy metal cations from weakly acidic to weakly basic solutions.

The resin features:

  • Monodispersed bead size distribution (uniform size)
  • Enlarged bead size
  • High mechanical and osmotic stability
  • High kinetics for good capacity utilization

It is particularly suitable for:

  • Concentration, extraction, and recovery of heavy metals from hydrometallurgical solutions, especially by Resin-in-Pulp processes.

Physical and Chemical Properties

  • Ionic form as shipped: Na⁺
  • Functional group: iminodiacetic acid
  • Matrix: crosslinked polystyrene
  • Structure: macroporous
  • Appearance: beige, opaque
  • Total capacity (H-Form): min. 2.0 eq/l
  • Uniformity Coefficient: max. 1.1
  • Mean bead size: 0.79 ± 0.05 mm
  • Bulk density: approx. 720 g/l (± 5 %)
  • Density: approx. 1.1 g/ml
  • Water retention: 55 - 60 wt. %
  • Volume change (Na⁺ --> H⁺): max. -25 vol. %
  • Stability (pH-range): 0 - 14
  • Storability: max. 2 years
  • Storage temperature range: -20 °C to +40 °C

Recommended Operating Conditions

  • Operating temperature: max. 80 °C
  • Operating pH-range: 1.5 - 9
  • Bed depth: min. 1000 mm
  • Specific pressure drop (15 °C): approx. 1.1 kPa·h/m²
  • Pressure drop: max. 250 kPa
  • Linear velocity (backwash, 20 °C): approx. 10 m/h
  • Bed expansion (20 °C, per m/h): approx. 4 vol. %
  • Freeboard (backwash, extern / intern): 80 vol. %

Regeneration:

  • Regenerant: HCl or H₂SO₄
  • Regenerant concentration: approx. 5 - 20 wt. % (depending on application)
  • Linear velocity (regeneration): approx. 5 m/h
  • Linear velocity (rinsing): approx. 5 m/h

Conditioning:

  • Conditioning: NaOH
  • Conditioning concentration: approx. 4 wt. %
  • Linear velocity (conditioning): approx. 5 m/h
  • Linear velocity (rinsing): approx. 5 m/h

Rinse water requirement:

  • Slow / fast: approx. 5 BV
  • Total: approx. 5 BV

Additional Information & Regulations

Safety precautions: Strong oxidants, e.g., nitric acid, can cause violent reactions with ion exchange resins. Consult the Safety Data Sheet for detailed information on product description, transport, storage, handling, safety, and ecology.

Disposal: In the European Community, ion exchange resins must be disposed of according to the European waste nomenclature.

Storage: It is recommended to store ion exchange resins above the freezing point of water, under roof, in dry conditions, and without direct sunlight. If the resin freezes, allow it to thaw gradually at ambient temperature before handling or use. Do not attempt to accelerate thawing.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.