Datasheet summary
LEWATIT® NM 60
PDF datasheet mirror for LEWATIT® NM 60 (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
- Product Name: Lewatit® NM 60
- Type: Highly regenerated mixed bed ion exchange resin
- Composition: 1:1 chemically equivalent mixture of a type 1, strong base anion exchange resin and a strong acid cation exchange resin.
- Functional Groups: Quaternary ammonium (anion), Sulfonic acid (cation)
- Matrix: Styrenic
- Structure: Gel
- Appearance: Dark brown (anion component) / Yellow translucent (cation component)
Applications
Lewatit® NM 60 is especially suited for:
- Mixed bed units for polishing after primary demineralization systems
- Electronic industries
- Small industrial plants (e.g., refilling of starter batteries or coolant circuits)
- Removal of radioactive waste
- Demineralization systems
Specified Data
- Uniformity Coefficient: max. 1.8
- Effective Size (d10): 0.40-0.65 mm
- Mixed Bed Test (Column Capacity Endpoint): min. 0.55 eq/L
- Mixed Bed Test (Polishing Quality NaCl Exhaustion): min. 0.02 MOhm·cm
Typical Physical and Chemical Properties
- Bulk Density (for shipment, +/- 5%): 690 g/L
- Density: approx. 1.1 g/mL
- Water Retention (delivery form): approx. 50-60% by weight
- Volume Change (during exhaustion): max. approx. -15%
- Stability pH Range: 0-14
- Storage Time (after delivery): max. 2 years
- Storage Temperature Range: -20 to +40 °C
Operating Parameters
- Operating Temperature: max. 60 °C
- Operating pH Range (during exhaustion): 0-14
- Bed Depth (for single column): min. 600 mm
- Specific Pressure Loss (15°C): 1.5 kPa·h/m²
- Max. Pressure Loss (during operation): 200 kPa
- Specific Flow Rate: max. 50 BV/h
Additional Information
- Safety Precautions: Strong oxidants, e.g., nitric acid, can cause violent reactions. Consult the Safety Data Sheet for transport, storage, handling, safety, and ecology information.
- Disposal: In the European Community, dispose of ion exchange resins according to the European Waste Nomenclature.
- Storage: Recommended to store above freezing point, under roof, dry, and out of direct sunlight. If frozen, allow to thaw gradually at ambient temperature. Packaging stability is limited to 24 months.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.