Datasheet summary
LEWATIT® NM 60 SG
PDF datasheet mirror for LEWATIT® NM 60 SG (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product Identification
Lewatit® NM 60 SG is a heterodisperse, gel type, high capacity, high purity mixed ion exchange resin. It is prepared with a 1:1 chemically equivalent ratio of cation to anion resin.
This product is designed for non-regenerable applications.
Operating Limits
- Stability pH range: 0-14
- Operating temperature: max. 40 °C
- Operating pH range during exhaustion: 0-14
- Max. pressure loss during operation: 200 kPa
Feed Water
- Bed depth for single column: min. 600 mm
- Specific pressure loss (15°C): 1.5 kPa*h/m²
- Specific flow rate: max. 50 BV/h
Product Water Quality
- Mixed bed test (column capacity) endpoint: min. 0.02 MOhm*cm resistivity
- Ultrapure water rinse test (resistivity) after 80 BV: min. 18 MOhm*cm
- Ultrapure water rinse test delta TOC after 80 BV: max. 5 ppb
Electrical
- Not specified.
Mechanical / Hydraulic
- Common Description: H⁺/OH⁻ functional group, Quaternary ammonium/sulfonic acid type, Styrenic matrix, Gel structure.
- Appearance: Dark brown / Yellow translucent
- Uniformity coefficient: max. 1.8
- Effective size (d10): 0.40-0.65 mm
- Mixed bed test (column capacity): min. 0.55 eq/L
- Bulk density for shipment (+/- 5%): 690 g/L
- Density: approx. 1.1 g/mL
- Water retention (delivery form): approx. 50-60 % by weight
- Volume change (during exhaustion): max. approx. -15 %
Storage and Handling
- Storage time (after delivery): max. 1 year
- Storage temperature range: -20 - +40 °C
- Recommended storage conditions: Above freezing point of water, under roof, in dry conditions, without direct sunlight.
- Handling if frozen: Allow to thaw gradually at ambient temperature before handling or use. Do not accelerate thawing.
- Packaging stability: Limited to 24 months under recommended storage conditions.
- Safety precautions: Avoid contact with strong oxidants like nitric acid. Observe the Safety Data Sheet.
- Disposal: Follow European waste nomenclature in the European Community.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.