Datasheet summary
LEWATIT® S 2328
PDF datasheet mirror for LEWATIT® S 2328 (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
Lewatit® S 2328 is a food grade, macroporous, strongly acidic cation exchange resin based on a styrene-divinylbenzene copolymer. It is bead-shaped and has a special bead size distribution.
- Common Description: H⁺ form, Sulfonic acid functional group, Styrenic matrix, Macroporous structure
- Delivery form: Beige-gray, opaque beads
Operating limits
- Stability pH range: 0-14
- Stability temperature range: 1-120 °C
- Operating temperature (max.): 120 °C
- Operating pH range during exhaustion: 0-14
Feed water
- Bed depth for single column (min.): 800 mm
- Freeboard during backwash (min.): 80-100 vol. %
Product water
No specific parameters are listed in the extract.
Electrical
No electrical parameters are listed in the extract.
Mechanical / hydraulic
- Uniformity coefficient (max.): 1.7
- Range of size for >90 vol% of all beads: 0.315-1.25 mm
- Effective size (d₁₀): 0.48-0.58 mm
- Total capacity (delivery form) (min.): 1.0 eq/L
- Bulk density for shipment (+/- 5%): 730 g/L
- Density (approx.): 1.1 g/mL
- Water retention (delivery form) (approx.): 67-73 % by weight
- Volume change (Na⁺ - H⁺) (max. approx.): 12 %
- Backwash bed expansion per m/h (20°C): 7 %
- Specific pressure loss (15°C): 1.1 kPa*h/m²
- Max. pressure loss during operation: 250 kPa
- Specific flow rate (max.): 2 BV/h
Regeneration
HCl Regeneration
- Concentration (approx.): 4-6 wt. %
- Quantity co-current (min.): 100 g/L resin
- Quantity counter-current (min.): 55-65 g/L resin
H₂SO₄ Regeneration
- Concentration (approx.): 1.5-3 wt. %
- Quantity co-current (min.): 150 g/L resin
- Quantity counter-current (min.): 90 g/L resin
Rinse Steps
- Regeneration contact time (min.): 20 minutes
- Slow rinse at regeneration flow rate: 2 BV
- Fast rinse at service flow rate: 4 BV
Additional Information
- Safety precautions: Strong oxidants can cause violent reactions. Observe Safety Data Sheet.
- Storage: Recommended to store above freezing point, under roof, dry, out of direct sunlight. If frozen, thaw gradually at ambient temperature.
- Storage time: Packaging stability limited to 24 months. Use within this timeframe or check packaging condition regularly.
- Storage temperature range: -20 - +40 °C
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)