LEWATIT® TP 106

PDF datasheet mirror for LEWATIT® TP 106 (Lanxess LEWATIT). Verify with OEM before design.

Summary

Product identification

Lewatit® TP 106 is a strong base anion exchange resin.

  • Common Description: Gel-type, polystyrene-based, heterodisperse particle size distribution.
  • Delivery form: Cl⁻
  • Functional group: Quaternary ammonium
  • Matrix: Styrenic
  • Structure: Gel
  • Appearance: White, opaque

Applications

Lewatit® TP 106 is particularly applicable for the removal of traces of perchlorate, chlorate, bromate, and other soft anions from various water and process streams, especially those with a high background of chloride and sulfate.

A special start-up procedure is required for potable water treatment.

Specified Data

  • Uniformity coefficient: max. 1.7
  • Effective size (d10): 0.40-0.55 mm
  • Fines (less than 0.315 mm): max. 1 vol %
  • Total capacity (delivery form): min. 0.65 eq/L

Note: The values given in this section are preliminary and can be subject to adjustments.

Typical Physical and Chemical Properties

  • Bulk density for shipment (+/- 5%): 690 g/L
  • Water retention (delivery form): approx. 37-47 wt %
  • Stability pH range: 0-14
  • Stability temperature range: 1-80 °C
  • Storage time (after delivery): max. 2 years
  • Storage temperature range: -20 - +40 °C

Note: The values given in this section are preliminary and can be subject to adjustments.

Operation

  • Operating temperature: max. 80 °C
  • Bed depth for single column: min. 800 mm
  • Max. pressure loss during operation: 250 kPa
  • Freeboard during backwash: min. 80-100 vol %

Additional Information & Regulations

  • Safety precautions: Strong oxidants, such as nitric acid, can cause violent reactions. Observe the Safety Data Sheet.
  • Disposal: Dispose of in accordance with the European waste nomenclature.
  • Storage: Store under roof in dry conditions, above freezing point and out of direct sunlight. If frozen, thaw gradually at ambient temperature. Recommended use within 24 months of delivery; check packaging condition thereafter.