Summary

Product identification

  • Product Name: LEWATIT® UltraPure 1211 MD
  • Product Type: Gel type, strongly acidic cation exchange resin (SAC)
  • Matrix: Crosslinked polystyrene
  • Functional Group: Sulfonic acid
  • Structure: Gel type beads
  • Appearance: Black - brown
  • Ionic form as shipped: Na⁺

Operating limits

  • pH range: 0 - 14
  • Maximum operating temperature: 120 °C
  • Storability: 2 years
  • Storage temperature range: -20 - +40 °C

Feed water

  • Application: Demineralization of water in the production of ultra pure water.
  • Leaching of organics: Less than 50 ppb.

Product water

  • Resistivity: min. 4.0 MOhm*cm (as a single component, ca. 80 BV)
  • Delta TOC: max. 50 ppb

Electrical

  • Not specified.

Mechanical / hydraulic

  • Uniformity Coefficient: max. 1.1
  • Mean bead size: 0.62 (+/-0.05) mm
  • Total capacity: min. 2.2 eq/l
  • Bulk density: approx. 840 g/l (+/- 5 %)
  • Density: approx. 1.30 g/ml
  • Water retention: 41 - 46 wt. %
  • Volume change (Na⁺ --> H⁺): max. 10 vol. %
  • Bed depth: min. 800 mm
  • Specific pressure drop (15 °C): approx. 1.0 kPa*h/m²
  • Pressure drop: max. 200 kPa
  • Linear velocity (operation): max. 60 m/h
  • Linear velocity (backwash, 20 °C): approx. 15 m/h
  • Freeboard (backwash, extern / intern): min. 60 vol. %
  • Bed expansion (20 °C, per m/h): approx. 4 vol. %

Regeneration (Counter-current)

  • Regenerant (HCl):
    • Quantity: approx. 50 g/l
    • Concentration: 4 - 6 wt. %
    • Linear velocity: approx. 5 m/h
    • Rinse water requirement (slow/fast): approx. 2.5 BV
  • Regenerant (H₂SO₄):
    • Quantity: approx. 80 g/l
    • Concentration: 1.5 - 4 wt. %**
    • Linear velocity: approx. 10 - 20 m/h
    • Rinse water requirement (slow/fast): approx. 5 BV

Regeneration (Co-current)

  • Regenerant (HCl):
    • Quantity: approx. 100 g/l
    • Concentration: approx. 6 - 10 wt. %
    • Linear velocity: approx. 5 m/h
    • Rinse water requirement (slow/fast): approx. 2.5 BV
  • Regenerant (H₂SO₄):
    • Quantity: approx. 150 g/l
    • Concentration: approx. 1.5 - 3 wt. %**
    • Linear velocity: approx. 10 - 20 m/h
    • Rinse water requirement (slow/fast): approx. 5 BV
  • Linear velocity (rinsing): approx. 5 m/h (for HCl and H₂SO₄)