LEWATIT® UltraPure 1216 MD

PDF datasheet mirror for LEWATIT® UltraPure 1216 MD (Lanxess LEWATIT). Verify with OEM before design.

Summary

Product identification

Product Name: Lewatit® UltraPure 1216 MD Product Type: Gel type, strongly acidic cation exchange resin (SAC) Matrix: Styrene-divinylbenzene copolymer Bead Size: Monodispersed (uniform particles) Application: Polishing systems for the production of ultrapure water. Optimized for use with Lewatit® UltraPure 1243 MD in mixed-bed systems.

Operating limits

  • Operating Temperature: max. 60 °C
  • Operating pH Range (during exhaustion): 0-14
  • Max. Pressure Loss (during operation): 200 kPa
  • Bed depth (single column): min. 800 mm
  • Specific flow rate: max. 100 BV/h
  • Specific pressure loss (15°C): 1.5 kPa*h/m²

Feed water

No specific feed water parameters are listed, but the product is designed for polishing systems to achieve ultrapure water.

Product water

  • Ultrapure water rinse test (resistivity): min. 12 MOhm*cm after 80 BV
  • Ultrapure water rinse test delta TOC: max. 10 ppb after 80 BV

Electrical

Not applicable.

Mechanical / hydraulic

  • Uniformity coefficient: max. 1.1
  • Mean bead size (d₅₀): 0.55 (+-0.05) mm
  • Total capacity (delivery form): min. 2.1 eq/L
  • Bulk density (for shipment +/- 5%): 790 g/L
  • Density (approx.): 1.22 g/mL
  • Water retention (delivery form): approx. 45-50 % by weight
  • Volume change (H⁺ - Na⁺): max. approx. -8 %
  • Friability: >95 vol % at >200 g/bead

Chemical properties

  • Functional group: Strongly acidic cation exchange
  • Ionic conversion H⁺: min. 99.9 eq. %
  • Stability pH range: 0-14

Regeneration

  • HCl regeneration concentration: approx. 4-6 wt. %
    • Quantity (co-current): min. 100 g/L resin
    • Quantity (counter-current): min. 55 g/L resin
  • H₂SO₄ regeneration concentration: approx. 1.5-8 wt. %
    • Quantity (co-current): min. 120 g/L resin
    • Quantity (counter-current): min. 80 g/L resin
  • Regeneration contact time: min. 20 minutes
  • Rinse (slow at regeneration flow rate): min. 2 BV
  • Rinse (fast at service flow rate): min. 2 BV

Storage and Handling

  • Storage time (after delivery): max. 1 year
  • Storage temperature range: -20 - +40 °C
  • Recommended Storage: Above freezing point of water, under roof, in dry conditions, without direct sunlight.
  • Frozen Resin: Thaw gradually at ambient temperature; do not mechanically handle or accelerate thawing.
  • Safety: Observe safety data sheet. Avoid contact with strong oxidants.
  • Disposal: According to European waste nomenclature.
  • Packaging Stability: Limited to 24 months under recommended storage conditions. Check packaging condition if stored longer.