Summary

Product identification

  • Product name: Lewatit® UltraPure 1221 MD
  • Type: Strongly acidic cation exchange resin (SAC)
  • Matrix: Styrenic, macroporous structure
  • Bead type: Monodispersed (uniform particle)
  • Functional group: Sulfonic acid
  • Delivery form: Na⁺ form
  • Appearance: Beige, grey

Operating limits

  • Operating temperature: max. 140 °C
  • Operating pH range (during exhaustion): 2-14
  • Stability pH range: 0.1-14
  • Storage temperature range: -20 - +40 °C
  • Storage time (after delivery): max. 2 years
  • Max. pressure loss during operation: 300 kPa

Feed water

  • Regeneration concentration (HCl): approx. 4-6 wt.%
  • Regeneration quantity (HCl, co-current): min. 100 g/L resin
  • Regeneration quantity (HCl, counter-current): min. 55 g/L resin
  • Regeneration concentration (H₂SO₄): approx. 1.5-8 wt.%
  • Regeneration quantity (H₂SO₄, co-current): min. 120 g/L resin
  • Regeneration quantity (H₂SO₄, counter-current): min. 80 g/L resin
  • Regeneration contact time: min. 20 minutes
  • Slow rinse at regeneration flow rate: min. 2 BV
  • Fast rinse at service flow rate: min. 2 BV
  • Backwash bed expansion (at 20°C): 4.5 % per m/h
  • Specific pressure loss (at 15°C): 0.8 kPa·h/m²
  • Specific flow rate: max. 100 BV/h
  • Bed depth for single column: min. 800 mm

Product water

  • Ultrapure water rinse test (resistivity) after 80 BV: min. 4 MOhm·cm
  • Ultrapure water rinse test delta TOC after 80 BV: max. 50 ppb

Electrical

  • No specific electrical parameters were listed.

Mechanical / hydraulic

  • Uniformity coefficient: max. 1.1
  • Mean bead size (d50): 0.65 (±0.05) mm
  • Total capacity (delivery form): min. 1.7 eq/L
  • Bulk density for shipment (±5%): 740 g/L
  • Density: approx. 1.24 g/mL
  • Water retention (delivery form): approx. 52-57 wt.%
  • Volume change (Na⁺ - H⁺): max. approx. 8 %

Additional Information

  • Safety: Avoid contact with strong oxidants like nitric acid. Observe the safety data sheet.
  • Disposal: Dispose according to European waste nomenclature.
  • Storage: Store above freezing point, dry, under roof, out of direct sunlight. If frozen, thaw gradually at ambient temperature. Packaging stability is limited to 24 months.

Disclaimer: This extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.