Back to Lanxess LEWATIT
Lanxess logo

Datasheet summary

LEWATIT® UltraPure 1261 MD

PDF datasheet mirror for LEWATIT® UltraPure 1261 MD (Lanxess LEWATIT). Verify with OEM before design.

Summary

Product identification

  • Product Name: Lewatit® UltraPure 1261 MD
  • Type: Macroporous, strongly basic anion exchange resin (SBA, type I)
  • Matrix: Crosslinked polystyrene
  • Structure: Macroporous
  • Appearance: Beige, opaque
  • Functional group: Quaternary amine, type I
  • Delivery form: Cl⁻

Operating limits

  • Operating temperature: max. 40 °C
  • Operating pH-range: 0 - 12
  • Pressure drop: max. 300 kPa

Feed water / Product water

  • Ultra pure water test delta TOC: max. 50 ppb
  • Specific resistivity: min. 4.0 MOhm*cm (as a single component, ca. 80 BV)

Electrical

  • Not applicable.

Mechanical / hydraulic

  • Uniformity coefficient: max. 1.1
  • Mean bead size: 0.65 (+/- 0.05) microns
  • Bulk density: 640 g/L (+/- 5 %)
  • Density: approx. 1.06 g/ml
  • Water retention: 60 - 65 wt. %
  • Bed expansion (at 20°C, per m/h): 0 - 14 vol. %
  • Storability (of the product): max. 12 years (at < 25°C: -20 - +40 months)

Operating conditions

  • Bed depth: min. 800 mm
  • Specific pressure drop (15 °C): approx. 0.8 kPa*h/m²
  • Linear velocity (Operation): max. 60 m/h
  • Linear velocity (Backwash at 20 °C): approx. 5 m/h
  • Linear velocity (Rinsing): approx. 5 m/h
  • Bed expansion (Backwash at 20 °C, per m/h): approx. 18 vol. %
  • Freeboard (Backwash, extern / intern): 100 vol. %

Regeneration

  • Regenerant (Counter-current & Co-current): NaOH
  • Regenerant Quantity (Counter-current): approx. 50 g/L
  • Regenerant Concentration (Counter-current): approx. 2 - 4 wt. %
  • Regenerant Quantity (Co-current): approx. 100 g/L
  • Regenerant Concentration (Co-current): approx. 3 - 5 wt. %
  • Linear velocity (Regeneration, Counter-current): approx. 5 m/h
  • Linear velocity (Regeneration, Co-current): approx. 5 m/h
  • Rinse water requirement (slow / fast, Counter-current): approx. 2.5 BV
  • Rinse water requirement (slow / fast, Co-current): approx. 2.5 / 8 BV

Additional Information

  • Safety precautions: Strong oxidants can cause violent reactions. Observe Safety Data Sheet.
  • Storage: Recommended above freezing point, dry, under roof, out of direct sunlight. If frozen, thaw gradually at ambient temperature.

Disclaimer: This extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.