Back to Mitsubishi
Mitsubishi logo

Datasheet summary

DIAION SAF10DL

PDF datasheet mirror for DIAION SAF10DL (Mitsubishi). Verify with OEM before design.

Summary

Product identification

  • Grade Name: DIAION™ SAF10DL
  • Type: Strong Base Anion
  • Matrix: Styrene-DVB, Gel
  • Functional Group: Type I (trimethyl ammonium groups)
  • Ionic Form: Cl⁻

DIAION™ SAF10DL is a gel type strongly basic anion exchange resin. It has higher crosslinkages and low-odor and low reachable properties. It is recommended for a wide range of applications, especially in manufacturing drinking water and refining sugar liquors.

Operating limits

  • Maximum Operating Temperature: 80 °C (Cl⁻ form), 60 °C (OH⁻ form)
  • Operating pH Range: 0 - 14

Feed water

  • Outlet ΔTOC: 200 ppb maximum

Recommended Operating Conditions

  • Minimum Bed Depth: 800 mm
  • Service Flow Rate: 10 - 60 m/h
  • Regenerant: NaOH
  • Regenerant Concentration: 2 - 8 % NaOH
  • Regenerant Level: 50 - 200 g/L
  • Regenerant Flow Rate: 2 - 8 m/h
  • Total Rinse Requirement: 2 - 10 BV

Specification

  • Whole Bead Count: 90 % minimum
  • Salt Splitting Capacity: 1.3 meq/mL minimum
  • Water Content: 39 - 47 %
  • Particle Size Distribution on 1180 μm: 5 % maximum
  • Particle Size Distribution through 500 μm: 1 % maximum
  • Effective Size: 0.50 mm minimum
  • Uniformity Coefficient: 1.6 maximum

Typical Properties

  • Shipping Density: 690 g/L
  • Mean Particle Size: 670 μm
  • Particle Density (Cl⁻): 1.08 g/mL
  • Total Swelling (Cl⁻ to OH⁻): 22 %

Hydraulic Characteristics

The approximate pressure drop at various temperatures and flow rates for each meter of bed depth of DIAION™ SAF10DL (Cl⁻ form) resin in normal downflow operation is shown in the graphs in the original document.


Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.