Back to Mitsubishi
Mitsubishi logo

Datasheet summary

DIAION UBK08HUP

PDF datasheet mirror for DIAION UBK08HUP (Mitsubishi). Verify with OEM before design.

Summary

Product identification

  • Grade Name: DIAIONTM UBK08HUP
  • Type: Strong Acid Cation
  • Matrix: Styrene-DVB, Gel
  • Functional Group: Sulfonic acid
  • Ionic Form: H⁺

Operating limits

  • Maximum Operating Temperature: 120 ℃
  • Operating pH Range: 0 - 14
  • Minimum Bed Depth: 800 mm

Feed water

  • Service Flow Rate: 10 - 40 m/h
  • Regenerant: HCl, H₂SO₄
  • Regenerant Concentration:
    • HCl: 4 - 10 %
    • H₂SO₄: 1 - 4 %
  • Regenerant Level: 30 - 150 g/L
  • Regenerant Flow Rate: 2 - 10 m/h
  • Total Rinse Requirement: 2 - 10 BV

Product water

  • Outlet resistivity: 12 MΩ‧cm max.
  • ΔTOC: 20 ppb min.

Mechanical / hydraulic

  • Shipping Density: 800 g/L
  • Particle Density: 1.20 g/mL
  • Total Swelling (Na⁺ to H⁺): 9 %
  • Whole Bead Count: 90 min.
  • Water Content: 50 - 56 %
  • Average Diameter: 620 ± 50 μm
  • Uniformity Coefficient: 1.10 max.

Specification

  • Salt Splitting Capacity: 1.8 meq/mL min.
  • Ionic Conversion (H⁺): 95 % min.