Purolite C145H

PDF datasheet mirror for Purolite C145H (Purolite). Verify with OEM before design.

Summary

Product identification

Purolite C145H is a Polystyrenic Macroporous, Strong Acid Cation Resin in Hydrogen form.

Typical Physical & Chemical Characteristics

  • Polymer Structure: Macroporous polystyrene crosslinked with divinylbenzene
  • Appearance: Spherical Beads
  • Functional Group: Sulfonic Acid
  • Ionic Form: H⁺ form
  • Total Capacity: 1.5 eq/L (32.8 Kgr/ft³) (Na⁺ form)
  • Moisture Retention: 61 - 66 % (H⁺ form)
  • Particle Size Range: 300 - 1200 µm
  • Fines (< 300 µm): 1 % (max.)
  • Uniformity Coefficient: 1.7 (max.)
  • Reversible Swelling (Na⁺ → H⁺): 6 % (max.)
  • Specific Gravity: 1.17
  • Shipping Weight (approx.): 735 - 770 g/L (45.9 - 48.1 lb/ft³)
  • Temperature Limit (H⁺ form): 120 °C (248.0 °F)
  • Temperature Limit (Na⁺ form): 140 °C (284.0 °F)

Principal Applications

  • Demineralization

Advantages

  • Very resistant to osmotic shock
  • High porosity

Hydraulic Characteristics

Backwash

  • Bed Expansion: Bed should be expanded between 50 and 70% for at least 10 to 15 minutes during up-flow backwash.
  • Initial Classification: Approximately 30 minutes of expansion is usually sufficient when first putting into service.
  • Factors Affecting Expansion: Bed expansion increases with flow rate and decreases with influent fluid temperature. Caution is needed to avoid resin loss due to over-expansion.

Pressure Drop

  • The pressure drop across the resin bed depends on particle size distribution, bed depth, voids volume, flow rate, and influent solution viscosity.
  • Factors such as particulate matter, abnormal resin compressibility, or incomplete bed classification can increase head loss.
  • Service Flow Rates: May vary from 10 to 40 BV/h depending on influent water quality, application, and plant design.

Typical Packaging

  • 1 ft³ Sack
  • 25 L Sack
  • 5 ft³ Drum (Fiber)
  • 1 m³ Supersack
  • 42 ft³ Supersack

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.