SuperGel SGC 650

PDF datasheet mirror for SuperGel SGC 650 (Purolite). Verify with OEM before design.

Summary

Product identification

  • Product Name: SuperGel SGC 650
  • Product Type: SuperGel Strong Acid Cation Resin, Uniform Size for Condensate Polishing and Mixed Bed Demineralization
  • Functional Groups: Sulfonic acid
  • Polymer Matrix Structure: Crosslinked Styrene-DVB Gel
  • Ionic Form, as shipped: H⁺

Typical Physical & Chemical Characteristics

  • Physical Form and Appearance: Hard Dark Spherical beads
  • Total Exchange Capacity, H⁺ form: ≥2.0 eq/l min. (43.6 kgr/ft³ as CaCO₃)
  • Moisture Retention (H⁺ form): 46 - 50%
  • Free Moisture: 1.5%
  • Crush Strength: Average min. 700 g/bead; > 200 g/bead 99% min.
  • Shipping Weight (approx.): 770 - 790 g/l (48 lb/ft³)
  • Mean Particle Size: 650 ± 50 microns
  • Uniformity Coefficient: 1.1
  • Whole Perfect Beads: 97% min.
  • Reversible Swelling (Na⁺ ➔ H⁺): 8% max.
  • pH Limits: 0 - 14
  • Particle Density (H⁺ form): 1.21 g/ml (approx.)

Recommended Operating Conditions

  • Operating Temperature: 130°C (265°F) max. (H⁺ form)
  • Bed Depth, Minimum: 450 mm / 1.5 ft
  • Flow Rate:
    • Service/Fast Rinse: 5 - 60 m/h (2 - 24 gpm/ft²)
    • Service Condensate Polishing: 40 - 150 m/h (16 - 60 gpm/ft²)
    • Backwash: See Backwash Data (Fig. 1)
    • Co-current regeneration / Displacement Rinse: 1 - 10 m/h (0.4 - 4 gpm/ft²)
  • Total Rinse Requirement: 3 - 6 Bed Volumes
  • Regeneration Type: 1 - 10% H₂SO₄ or 3 - 8% HCl

Backwash Data

Figure 1 illustrates the backwash expansion data for SGC-650. The relationship between linear flow rate and bed expansion percentage is shown for both H⁺ and Na⁺ forms at 25°C (77°F). Formulas are provided to adjust for different temperatures.


Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.