Back to ResinTech
ResinTech logo

Datasheet summary

CG10 UPS

PDF datasheet mirror for CG10 UPS (ResinTech). Verify with OEM before design.

Summary

Product identification

  • Product Name: CG10-UPS
  • Product Type: STRONG ACID CATION
  • Polymer Matrix: Styrenic Gel
  • Functional Group: Sulfonic Acid
  • Ionic Form: Sodium
  • Crosslinking: 10%
  • Particle Size: Uniform Particle Size
  • Color: Amber

Typical Properties & Physical Characteristics

  • Physical Form: Spherical Beads
  • Particle Size: 20 to 40 US Mesh (400 - 841 μm)
  • % < 50 mesh (300µm): < 0.5 %
  • Minimum Sphericity: 95%
  • Uniformity Coefficient: 1.25
  • Reversible Swelling (Na to H): 4% to 8%
  • Temperature Limit: 280°F (138°C)
  • Capacity (meq/mL): 2.2
  • Moisture Retention: 39% to 45%
  • Shipping Weight: 52 - 54 lbs/ft³ (849 - 881 g/L)
  • Regenerability: Yes

Suggested Operating Conditions

  • Maximum continuous temperature: 280°F
  • Minimum bed depth: 24 inches
  • Backwash expansion: 25 to 50 percent
  • Maximum pressure loss: 25 psi
  • Operating pH range: 0 to 14 SU

Regenerant (Salt Cycle)

  • Concentration: 10 to 15 percent NaCl
  • Level: 4 to 15 lbs./cu.ft.
  • Flow rate: 0.5 to 1.5 gpm/cu.ft.
  • Contact time: >20 minutes

Displacement (Salt Cycle)

  • Flow rate: Same as dilution water
  • Volume: 10 to 15 gallons/cu.ft.

Rinse (Salt Cycle)

  • Flow rate: 1 to 10 gpm/cu.ft.
  • Volume: 35 to 60 gallons/cu.ft.

Service Flow Rate

  • Service flow rate: 1 to 10 gpm/cu.ft.

Applications

  • Softening - Industrial
  • Demineralization
  • Packed Beds
  • Condensate softeners
  • High flow rate applications

Packaging Options

  • 500 ml samples
  • 1 ft³ bags
  • 1 ft³ boxes
  • 1 ft³ drums
  • 7 ft³ drums
  • 42 ft³ supersacks

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.