Back to ResinTech
ResinTech logo

Datasheet summary

CG8 HP

PDF datasheet mirror for CG8 HP (ResinTech). Verify with OEM before design.

Summary

Product identification

  • Product Name: CG8-HP
  • Product Line: ResinTech
  • Type: Strong Acid Cation
  • Grade: High-Purity Grade
  • Polymer Matrix: Polystyrene Gel, 8% Crosslinked
  • Ionic Form: Sodium
  • Functional Group: Sulfonic Acid
  • Physical Form: Spherical Beads
  • Color: Amber

Typical Properties & Physical Characteristics

  • Particle Size: 16 to 50 US Mesh (297 - 1190 μm)
  • % < 50 mesh (300µm): < 1%
  • Minimum Sphericity: 93%
  • Uniformity Coefficient: 1.6
  • Reversible Swelling (Na to H): 5% to 9%
  • Capacity (meq/mL): 2.0
  • Moisture Retention: 42% to 49%
  • Shipping Weight: 51 - 53 lbs/ft³ (817 - 849 g/L)
  • Regenerability: Yes

Operating Limits

  • Maximum continuous temperature: 280°F (138°C)
  • Maximum pressure loss: 25 psi

Feed water

  • Iron content: Iron content in the feedwater should not be more than 1 mg/L Fe per each 17 mg/L of hardness.
  • Ammonia Removal: CG8-HP is slightly selective for ammonia compared to sodium, but hardness is much more preferred. Ammonia is not ionized at pH above 9 and is not well removed when the pH is significantly alkaline.

Suggested Operating Conditions

  • Sodium form:
    • Minimum bed depth: 24 inches
    • Backwash expansion: 25 to 50 percent
    • Operating pH range: 0 to 14 SU
    • Regenerant Concentration (NaCl): 10 to 15 percent
    • Regenerant level: 4 to 15 lbs./cu.ft.
    • Regenerant flow rate: 0.5 to 1.5 gpm/cu.ft.
    • Regenerant contact time: >20 minutes
    • Displacement flow rate: Same as dilution water
    • Displacement volume: 10 to 15 gallons/cu.ft.
    • Rinse flow rate: Same as service flow
    • Rinse volume: 35 to 60 gallons/cu.ft.
    • Service flow rate: 1 to 10 gpm/cu.ft.
  • Hydrogen cycle:
    • Regenerant Concentration (HCl): 5 to 10 percent
    • Regenerant Concentration (H₂SO₄): 1 to 8 percent

Mechanical / Hydraulic

  • Backwash Expansion:
    • 0.0 gpm/sq.ft.: 0% expansion
    • 3.0 gpm/sq.ft.: 0% expansion (at 40°F)
    • 6.0 gpm/sq.ft.: 20% expansion (at 40°F)
    • 9.0 gpm/sq.ft.: 40% expansion (at 40°F)
    • 12.0 gpm/sq.ft.: 60% expansion (at 40°F)
    • (Expansion percentages are also indicated at 60°F, 80°F, and 100°F for various flow rates)
  • Pressure Loss:
    • 0.0 gpm/sq.ft.: 0.0 psi/ft.
    • 0.4 gpm/sq.ft.: 0.0 psi/ft. (at 40°F)
    • 0.8 gpm/sq.ft.: 0.4 psi/ft. (at 40°F)
    • 1.2 gpm/sq.ft.: 0.8 psi/ft. (at 40°F)
    • 1.6 gpm/sq.ft.: 1.2 psi/ft. (at 40°F)
    • 2.0 gpm/sq.ft.: 1.6 psi/ft. (at 40°F)
    • 5.0 gpm/sq.ft.: 2.0 psi/ft. (at 40°F)
    • 10.0 gpm/sq.ft.: 2.4 psi/ft. (at 40°F)
    • 15.0 gpm/sq.ft.: 2.4 psi/ft. (at 40°F)
    • 20.0 gpm/sq.ft.: 2.4 psi/ft. (at 40°F)
    • (Pressure losses are also indicated at 60°F, 80°F, and 100°F for various flow rates)

Applications

  • Softening - Municipal
  • Radium Removal
  • Softening - Residential

Certifications

  • WQA Gold Seal* (NSF/ANSI/CAN 61: Drinking Water System Components - Health Effects)
  • Kosher Certified
  • FDA Compliance** (Paragraph 21CFR173.25 of the Food Additives Regulations of the US FDA)

Note: NSF/ANSI-61 compliance requires conditioning with a minimum 20 bed volume rinse prior to first use.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.