Summary

Product identification

  • Product Name: CN10
  • Product Type: STRONG ACID CATION
  • Polymer Matrix: Styrenic Gel
  • Functional Group: Sulfonic Acid
  • Ionic Form: Sodium
  • Crosslinking: 10%
  • Manufacturing: ResinTech, Inc. (Camden, NJ)
  • Description: Premium grade dark colored sodium form 10% crosslinked gel strong acid cation resin. Solvent free.

Applications

  • Softening - Industrial
  • Demineralization
  • Softening - High Temperature

Certifications

  • WQA Gold Seal
    • Meets NSF/ANSI 44: Residential Cation Exchange Water Softeners
    • Meets NSF/ANSI-61: Drinking Water System Components - Health Effects
    • Meets NSF/ANSI/CAN 372: Drinking Water System Components - Lead Content

Typical Properties & Physical Characteristics

  • Physical Form: Spherical Beads
  • Particle Size: 16 to 50 US Mesh (297 - 1190 μm)
  • % < 50 mesh (300µm): < 1%
  • Minimum Sphericity: 90%
  • Uniformity Coefficient: 1.6
  • Reversible Swelling (Na to H): 4% to 8%
  • Capacity (meq/mL): 2.2
  • Moisture Retention: 39% to 45%
  • Shipping Weight: 52 - 54 lbs/ft³ (833 - 865 g/L)
  • Color: Black
  • Regenerability: Yes

Operating Limits

  • Maximum continuous temperature: 280°F (138°C)

High Temperature Use

  • Suitable for operation at temperatures as high as 280°F.
  • At temperatures above 212°F, dissolved oxygen in the feedwater can damage the resin.
  • Oxygen levels in feed should be reduced to less than 0.05 ppm to ensure reasonable service life.

Suggested Operating Conditions

  • Maximum continuous temperature: 280°F
  • Minimum bed depth: 24 inches
  • Backwash expansion: 25 to 50 percent
  • Maximum pressure loss: 25 psi
  • Operating pH range: 0 to 14 SU

Regenerant (Sodium Form - Salt Cycle)

  • Regenerant Concentration: 10 to 15 percent NaCl
  • Regenerant level: 4 to 15 lbs./cu.ft.
  • Regenerant flow rate: 0.5 to 1.5 gpm/cu.ft.
  • Regenerant contact time: >20 minutes
  • Displacement flow rate: Same as dilution water
  • Displacement volume: 10 to 15 gallons/cu.ft.
  • Rinse flow rate: Same as service flow
  • Rinse volume: 35 to 60 gallons/cu.ft.

Regenerant (Hydrogen Cycle)

  • Regenerant Concentration: 5 to 10 percent HCl or 1 to 8 percent H₂SO₄

Flow Rates

  • Service flow rate: 1 to 10 gpm/cu.ft.

Mechanical / Hydraulic

Backwash Expansion

See the official PDF for exact tabulated values.

Pressure Loss

See the official PDF for exact tabulated values.

Packaging Options

  • 500 ml samples
  • 1 ft³ bags
  • 1 ft³ boxes
  • 1 ft³ drums
  • 7 ft³ drums
  • 42 ft³ supersacks

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.