Back to ResinTech
ResinTech logo

Datasheet summary

MBD-10

PDF datasheet mirror for MBD-10 (ResinTech). Verify with OEM before design.

Summary

Product identification

  • Product Name: MBD-10
  • Product Type: MIXED BED HIGH-PURITY MIXED BED
  • Polymer Matrix: Styrenic Gel
  • Ionic Form: Hydrogen & Hydroxide (H / OH FORM)
  • Functional Group: Sulfonic Acid / Trimethylamine
  • Revision: 1.2

Packaging Options

  • 500 ml samples
  • 1 ft³ bags
  • 1 ft³ boxes
  • 1 ft³ drums
  • 7 ft³ drums
  • 42 ft³ supersacks

Typical Properties & Physical Characteristics

  • Description: A mixture of a dark colored hydrogen form cation resin and a hydroxide form type 1 strong base anion resin. The resin ratio is 1:1 on an equivalent basis and the component resins are chosen to separate easily for regeneration. MBD-10 is intended for use in all mixed bed deionization applications that require high resistivity and high throughput capacity.
  • Physical Form: Spherical Beads
  • Particle Size: 16 to 50 US Mesh (297 - 1190 μm)
  • % < 50 mesh (300µm): < 1%
  • Reversible Swelling: H/OH to Na/Cl -15% to -17%
  • Temperature Limit: 140°F (60°C)
  • Capacity (meq/mL): 0.6
  • Moisture Retention: 53% to 65%
  • Shipping Weight: 42 - 44 lbs/ft³ (673 - 705 g/L)
  • Color: Black & Amber
  • Regenerability: Yes

Applications

  • Portable Exchange Deionization (PEDI)
  • In-Place Regeneration
  • Cartridge Applications

Suggested Operating Conditions

  • Maximum continuous temperature: 140°F
  • Maximum intermittent temperature: 180°F
  • Minimum bed depth: 24 inches
  • Backwash expansion: 50 to 100 percent
  • Maximum pressure loss: 25 psi
  • Operating pH range: 2 to 12 SU
  • Service flow rate (Working): 1 to 5 gpm per cu. ft.
  • Service flow rate (Polishing): 3 to 15 gpm per cu. ft.

Technical Data - Flow & Pressure

Backwash Expansion

gpm / sq.ft.Percent of Expansion
0.00˚F
1.020
2.040
3.060
4.080
  • Temperatures indicated for Backwash Expansion: 40°F, 60°F, 80°F, 100°F

Pressure Loss

gpm / sq.ft.psi / ft. of Resin
0.00.0
0.50.0
1.00.5
1.51.0
2.01.5
2.52.0
3.02.5
5.010.0
10.015.0
20.020.0
  • Temperatures indicated for Pressure Loss: 40°F, 60°F, 80°F, 100°F

Throughput Capacity (Gal/cu. ft.)

Mixed Bed throughput capacity is to a 1 µS/cm endpoint. TDS is based on NaCl. Capacity is based on virgin resin.

TDS (ppm as CaCO₃)Conductivity (µS/cm)No CO₂ or SiO₂5 ppm CO₂ or SiO₂10 ppm CO₂ or SiO₂
2 / 5111,83431,95318,639
5 / 12.544,73422,36714,911
10 / 2522,36714,91111,183
20 / 5011,1838,9477,456
50 / 1254,4734,0673,728
100 / 2502,2372,1302,033
200 / 5001,1181,0911,065
500 / 1250447443439
1,000 / 2500224223221

Disclaimer This extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.