Datasheet summary
MBD-10
PDF datasheet mirror for MBD-10 (ResinTech). Verify with OEM before design.
Summary
Product identification
- Product Name: MBD-10
- Product Type: MIXED BED HIGH-PURITY MIXED BED
- Polymer Matrix: Styrenic Gel
- Ionic Form: Hydrogen & Hydroxide (H / OH FORM)
- Functional Group: Sulfonic Acid / Trimethylamine
- Revision: 1.2
Packaging Options
- 500 ml samples
- 1 ft³ bags
- 1 ft³ boxes
- 1 ft³ drums
- 7 ft³ drums
- 42 ft³ supersacks
Typical Properties & Physical Characteristics
- Description: A mixture of a dark colored hydrogen form cation resin and a hydroxide form type 1 strong base anion resin. The resin ratio is 1:1 on an equivalent basis and the component resins are chosen to separate easily for regeneration. MBD-10 is intended for use in all mixed bed deionization applications that require high resistivity and high throughput capacity.
- Physical Form: Spherical Beads
- Particle Size: 16 to 50 US Mesh (297 - 1190 μm)
- % < 50 mesh (300µm): < 1%
- Reversible Swelling: H/OH to Na/Cl -15% to -17%
- Temperature Limit: 140°F (60°C)
- Capacity (meq/mL): 0.6
- Moisture Retention: 53% to 65%
- Shipping Weight: 42 - 44 lbs/ft³ (673 - 705 g/L)
- Color: Black & Amber
- Regenerability: Yes
Applications
- Portable Exchange Deionization (PEDI)
- In-Place Regeneration
- Cartridge Applications
Suggested Operating Conditions
- Maximum continuous temperature: 140°F
- Maximum intermittent temperature: 180°F
- Minimum bed depth: 24 inches
- Backwash expansion: 50 to 100 percent
- Maximum pressure loss: 25 psi
- Operating pH range: 2 to 12 SU
- Service flow rate (Working): 1 to 5 gpm per cu. ft.
- Service flow rate (Polishing): 3 to 15 gpm per cu. ft.
Technical Data - Flow & Pressure
Backwash Expansion
| gpm / sq.ft. | Percent of Expansion |
|---|---|
| 0.0 | 0˚F |
| 1.0 | 20 |
| 2.0 | 40 |
| 3.0 | 60 |
| 4.0 | 80 |
- Temperatures indicated for Backwash Expansion: 40°F, 60°F, 80°F, 100°F
Pressure Loss
| gpm / sq.ft. | psi / ft. of Resin |
|---|---|
| 0.0 | 0.0 |
| 0.5 | 0.0 |
| 1.0 | 0.5 |
| 1.5 | 1.0 |
| 2.0 | 1.5 |
| 2.5 | 2.0 |
| 3.0 | 2.5 |
| 5.0 | 10.0 |
| 10.0 | 15.0 |
| 20.0 | 20.0 |
- Temperatures indicated for Pressure Loss: 40°F, 60°F, 80°F, 100°F
Throughput Capacity (Gal/cu. ft.)
Mixed Bed throughput capacity is to a 1 µS/cm endpoint. TDS is based on NaCl. Capacity is based on virgin resin.
| TDS (ppm as CaCO₃) | Conductivity (µS/cm) | No CO₂ or SiO₂ | 5 ppm CO₂ or SiO₂ | 10 ppm CO₂ or SiO₂ |
|---|---|---|---|---|
| 2 / 5 | 111,834 | 31,953 | 18,639 | |
| 5 / 12.5 | 44,734 | 22,367 | 14,911 | |
| 10 / 25 | 22,367 | 14,911 | 11,183 | |
| 20 / 50 | 11,183 | 8,947 | 7,456 | |
| 50 / 125 | 4,473 | 4,067 | 3,728 | |
| 100 / 250 | 2,237 | 2,130 | 2,033 | |
| 200 / 500 | 1,118 | 1,091 | 1,065 | |
| 500 / 1250 | 447 | 443 | 439 | |
| 1,000 / 2500 | 224 | 223 | 221 |
Disclaimer This extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.