Datasheet summary
MBD-15-LTOC
PDF datasheet mirror for MBD-15-LTOC (ResinTech). Verify with OEM before design.
Summary
Product identification
- Product Name: MBD-15-LTOC
- Product Type: MIXED BED
- Product Line: ResinTech, Inc.®
- Grade: HIGH CAPACITY LOW TOC MIXED BED POLYSTYRENIC GEL H / OH FORM
- Revision: 1.1
ResinTech MBD-15-LTOC is a mixture of a dark-colored hydrogen form cation resin and a hydroxide form type 1 strong base anion resin in a 1:1 equivalent ratio. The LTOC grade is functionally tested to produce > 18 megohm resistivity and under 10 ppb of TOC.
Applications
- High Purity DI Water
- Portable Exchange Deionization (PEDI) - Low TOC
- Cartridge Applications
- In Place Regeneration
Typical Properties & Physical Characteristics
- Polymer Matrix: Styrenic Gel
- Ionic Form: Hydrogen & Hydroxide
- Functional Group: Sulfonic Acid / Trimethylamine
- Physical Form: Spherical Beads
- Particle Size: 16 to 50 US Mesh (297 - 1190 μm)
- % < 50 mesh (300µm): < 1%
- Reversible Swelling (H/OH to Na/Cl): -15% to -17%
- Temperature Limit: 140°F (60°C)
- Capacity (meq/mL): 0.6
- Moisture Retention: 53% to 65%
- Shipping Weight: 42 - 44 lbs/ft³ (673 - 705 g/L)
- Color: Brown / Black & Amber
- Regenerability: Yes
Suggested Operating Conditions
- Maximum continuous temperature: 140°F
- Maximum intermittent temperature: 180°F
- Minimum bed depth: 24 inches
- Backwash expansion: 50 to 100 percent
- Maximum pressure loss: 25 psi
- Operating pH range: 2 to 12 SU
- Service flow rate (Working): 1 to 5 gpm per cu. ft.
- Service flow rate (Polishing): 3 to 15 gpm per cu. ft.
Packaging Options
- 500 ml samples
- 1 ft³ bags
- 1 ft³ boxes
- 1 ft³ drums
- 7 ft³ drums
- 42 ft³ supersacks
Technical Data
Backwash Expansion
| gpm / sq.ft. | 40˚F | 60˚F | 80˚F | 100˚F |
|---|---|---|---|---|
| 0.0 | 0 | 0 | 0 | 0 |
| 1.0 | 20 | 40 | 60 | 80 |
| 2.0 | 100 |
Pressure Loss
| gpm / sq.ft. | 40˚F | 60˚F | 80˚F | 100˚F |
|---|---|---|---|---|
| 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 0.5 | ||||
| 1.0 | ||||
| 1.5 | ||||
| 2.0 | ||||
| 2.5 | ||||
| 3.0 | ||||
| 5.0 | 15.0 | |||
| 10.0 | 20.0 |
Throughput Capacity (Gal/cu. ft.)
| TDS (ppm as CaCO₃) | Conductivity (uS/cm) | No CO₂ or SiO₂ | 5 ppm CO₂ or SiO₂ | 10 ppm CO₂ or SiO₂ |
|---|---|---|---|---|
| 2/5 | 111,834 | 31,953 | 18,639 | |
| 5/12.5 | 44,734 | 22,367 | 14,911 | |
| 10/25 | 22,367 | 14,911 | 11,183 | |
| 20/50 | 11,183 | 8,947 | 7,456 | |
| 50/125 | 4,473 | 4,067 | 3,728 | |
| 100/250 | 2,237 | 2,130 | 2,033 | |
| 200/500 | 1,118 | 1,091 | 1,065 | |
| 500/1250 | 447 | 443 | 439 | |
| 1000/2500 | 224 | 223 | 221 |
Note: Mixed Bed throughput capacity is to a 1 µS/cm endpoint. TDS is based on NaCl. Capacity is based on virgin resin.
Disclaimer: This extracted summary may not include all figures, footnotes, or revisions. Contractual data must match the official OEM PDF revision used for the project.