Back to ResinTech
ResinTech logo

Datasheet summary

MBD-15

PDF datasheet mirror for MBD-15 (ResinTech). Verify with OEM before design.

Summary

Product identification

  • Product Name: MBD-15
  • Product Type: MIXED BED
  • Product Line: ResinTech
  • Revision: 1.1
  • Description: A mixture of a dark colored hydrogen form cation resin and a hydroxide form type 1 strong base anion resin. Intended for use in all mixed bed deionization applications that require high resistivity and high throughput capacity. The component resins are chosen to separate easily for regeneration.

Applications

  • Portable Exchange Deionization (PEDI)
  • In-Place Regeneration
  • Cartridge Applications

Typical Properties & Physical Characteristics

  • Polymer Matrix: Styrenic Gel
  • Ionic Form: Hydrogen & Hydroxide
  • Functional Group: Sulfonic Acid / Trimethylamine
  • Physical Form: Spherical Beads
  • Particle Size: 16 to 50 US Mesh (297 - 1190 μm)
  • % < 50 mesh (300µm): < 1%
  • Reversible Swelling (H/OH to Na/Cl): -15% to -17%
  • Temperature Limit: 140°F (60°C)
  • Capacity (meq/mL): 0.6
  • Moisture Retention: 53% to 65%
  • Shipping Weight: 42 - 44 lbs/ft³ (673 - 705 g/L)
  • Color: Brown / Black & Amber
  • Regenerability: Yes

Suggested Operating Conditions

  • Maximum continuous temperature: 140°F
  • Maximum intermittent temperature: 180°F
  • Minimum bed depth: 24 inches
  • Backwash expansion: 50 to 100 percent
  • Maximum pressure loss: 25 psi
  • Operating pH range: 2 to 12 SU
  • Service flow rate (Working): 1 to 5 gpm per cu. ft.
  • Service flow rate (Polishing): 3 to 15 gpm per cu. ft.

Backwash Expansion

Backwash expansion is shown graphically with percent of expansion versus flow rate (gpm/sq.ft.) at various temperatures (40°F, 60°F, 80°F, 100°F).

Pressure Loss

Pressure loss is shown graphically with psi/ft. of Resin versus flow rate (gpm/sq.ft.) at various temperatures (40°F, 60°F, 80°F, 100°F).

Throughput Capacity (Gal/cu. ft.)

Throughput capacity is listed in a table showing gallons per cubic foot versus Total Dissolved Solids (TDS) in ppm as CaCO₃ (or equivalent for specified ions). The table includes values for different feed water conditions:

  • No CO₂ or SiO₂
  • 5 ppm CO₂ or SiO₂
  • 10 ppm CO₂ or SiO₂

The TDS values are presented in two formats: "2/5", "5/12.5", "10/25", "20/50", "50/125", "100/250", "200/500", "500/1250", "1,000/2500".

Note: Mixed Bed throughput capacity is to a 1 µS/cm endpoint. TDS is based on NaCl. Capacity is based on virgin resin.

Packaging Options

  • 500 ml samples
  • 1 ft³ bags
  • 1 ft³ boxes
  • 1 ft³ drums
  • 7 ft³ drums
  • 42 ft³ supersacks

Disclaimer: This extracted text may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.