Back to ResinTech
ResinTech logo

Datasheet summary

MBD-16

PDF datasheet mirror for MBD-16 (ResinTech). Verify with OEM before design.

Summary

Product identification

  • Product Name: MBD-16
  • Product Type: MIXED BED, HIGH-PURITY MIXED BED
  • Manufacturer: ResinTech, Inc.
  • Revision: 1.0

ResinTech MBD-16 is a 2:3 volumetric mixture of CG10-H-BL (a dark-colored hydrogen form cation resin) and SBG1P-OH (a hydroxide form type 1 porous strong base anion resin).

Applications

  • Portable Exchange Deionization (PEDI)
  • Mixed bed deionization applications requiring high resistivity and high throughput capacity.
  • PEDI applications to remove bulk TDS from raw waters or trace levels of TDS following reverse osmosis or other membrane processes.

Typical Properties & Physical Characteristics

  • Polymer Matrix: Styrenic Gel
  • Functional Group: Sulfonic Acid / Trimethylamine
  • Ionic Form: Hydrogen & Hydroxide
  • Physical Form: Spherical Beads
  • Particle Size: 16 to 50 US Mesh (297 - 1190 μm)
  • % < 50 mesh (300µm): < 1%
  • Reversible Swelling (H/OH to Na/Cl): -15% to -17%
  • Temperature Limit: 250°F (121°C)
  • Capacity (meq/mL): 0.6
  • Moisture Retention: 56% to 64%
  • Shipping Weight: 42 - 44 lbs/ft³ (673 - 705 g/L)
  • Color: Brown / Black & Amber
  • Regenerability: Yes
  • Crosslinking: 10%
  • Resin Ratio: 2:3 volumetric mixture (CG10-H-BL : SBG1P-OH)

Suggested Operating Conditions

  • Maximum continuous temperature: 140°F
  • Maximum intermittent temperature: 180°F
  • Minimum bed depth: 24 inches
  • Backwash expansion: 50 to 75 percent
  • Maximum pressure loss: 25 psi
  • Operating pH range: 2 to 12 SU
  • Service flow rate (Working): 1 to 5 gpm per cu. ft.
  • Service flow rate (Polishing): 3 to 15 gpm per cu. ft.

Note: These guidelines describe average low risk operating conditions. They are not intended to be absolute minimums or maximums. For operation outside these guidelines, contact ResinTech Technical Support.

Backwash Expansion

gpm / sq.ft.40˚F60˚F80˚F100˚F
00000
1.020406080

Pressure Loss

gpm / sq.ft.40˚F60˚F80˚F100˚F
0.00.00.00.00.0
0.50.51.01.52.0
5.010.015.020.025.0

Throughput Capacity (Gal/cu. ft.)

Mixed Bed throughput capacity is based on the stated inlet conductivity of neutral pH waters and run to a 1 µS/cm endpoint. TDS is based on NaCl (2.5µS/cm/ppm as CaCO₃). Different salts may have different contributions to TDS. Capacity is based on the anion component and is for virgin resin. Following the initial exhaustion and regeneration, subsequent cycles will likely be shorter, depending on how skillfully the resins are separated, regenerated, and remixed.

TDS (ppm as CaCO₃)No CO₂ or SiO₂5 ppm CO₂ or SiO₂10 ppm CO₂ or SiO₂
2/5111,83431,95318,639
5/12.544,73422,36714,911
10/2522,36714,91111,183
20/5011,1838,9477,456
50/1254,4734,0673,728
100/2502,2372,1302,033
200/5001,1181,0911,065
500/1250447443439
1,000/2500224223221

Packaging Options

  • 1 ft³ bags
  • 1 ft³ boxes
  • 1 ft³ drums
  • 7 ft³ drums
  • 42 ft³ supersacks

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.