Back to ResinTech
ResinTech logo

Datasheet summary

MBD-30

PDF datasheet mirror for MBD-30 (ResinTech). Verify with OEM before design.

Summary

Product identification

  • Product Name: MBD-30
  • Product Type: Mixed Bed, Color-Indicating, High-Capacity Mixed Bed, Polystyrene Gel, H/OH Form
  • Manufacturer: ResinTech, Inc.
  • Revision: 1.0

Polymer Matrix

  • Matrix Type: Styrenic Macroporous
  • Functional Group: Sulfonic Acid / Trimethylamine
  • Physical Form: Spherical Beads
  • Color: Amber & Blue (The anion component is dyed blue and turns amber as it exhausts)

Operating Limits

  • Maximum continuous temperature: 140°F (This is lower than the Temp Limit of 250°F (121°C) listed under TYPICAL PROPERTIES)
  • Operating pH range: 2 to 12 SU
  • Maximum pressure loss: 25 psi

Feed Water

  • Note on Capacity: Mixed Bed throughput capacity is based on stated inlet conductivity of neutral pH waters and run to a 1 µS/cm endpoint. TDS is based on NaCl (2.5 µS/cm/ppm as CaCO₃). Different salts may have different contributions to TDS. Capacity is based on the anion component and is for virgin resin. Subsequent cycles after initial exhaustion and regeneration will likely be shorter.

Product Water

  • Endpoint Conductivity: 1 µS/cm (for capacity calculations)

Mechanical / Hydraulic

  • Particle Size: 16 to 50 US Mesh (297 - 1190 µm)
  • Percent < 50 mesh (300 µm): < 1%
  • Reversible Swelling (H/OH to Na/Cl): -15% to -17%
  • Moisture Retention: 52% to 62%
  • Shipping Weight: 42 - 44 lbs/ft³ (673 - 705 g/L)
  • Minimum bed depth: 24 inches
  • Backwash expansion: 50 to 100 percent
  • Service flow rate: 1 to 5 gpm per cu. ft.

Backwash Expansion Chart

  • Chart axes: Percent of Expansion vs. gpm / sq.ft.
  • Temperatures indicated: 40°F, 60°F, 80°F, 100°F
  • See the official PDF for exact tabulated values.

Pressure Loss Chart

  • Chart axes: Pressure Loss (psi / ft. of Resin) vs. gpm / sq.ft.
  • Temperatures indicated: 40°F, 60°F, 80°F, 100°F
  • See the official PDF for exact tabulated values.

Throughput Capacity (Gal/cu. ft.)

Inlet TDS (ppm)No CO₂ or SiO₂5 ppm CO₂ or SiO₂10 ppm CO₂ or SiO₂
293,19526,62715,533
537,27818,63912,426
1018,63912,4269,320
209,3207,4566,213
503,7283,3893,107
1001,8641,7751,694
200932909888
500373369365
1,000186185185

Electrical

  • Ionic Form: Hydrogen & Hydroxide

Applications

  • Cartridge Applications
  • Aquarium
  • Steam Irons

Packaging Options

  • 500 ml samples
  • 1 ft³ bags
  • 1 ft³ boxes
  • 1 ft³ drums
  • 7 ft³ drums
  • 42 ft³ supersacks

Disclaimer This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.