Back to ResinTech
ResinTech logo

Datasheet summary

SBG2 HP

PDF datasheet mirror for SBG2 HP (ResinTech). Verify with OEM before design.

Summary

Product identification

  • Product Name: SBG2-HP
  • Product Line: ResinTech
  • Type: STRONG BASE ANION
  • Grade: HIGH-PURITY GRADE
  • Functional Group: Dimethylethanolamine
  • Polymer Matrix: Styrenic Gel
  • Ionic Form: Chloride
  • Physical Form: Spherical Beads

Operating limits

  • Maximum continuous temperature: 170°F (77°C)
  • Operating pH range: 0 to 14 SU
  • Maximum pressure loss: 20 psi

Feed water

  • Minimum bed depth: 24 inches
  • Backwash expansion: 25 to 50 percent

Product water

  • WQA Gold Seal Certified: For use in potable water applications.
  • NSF/ANSI-61 compliance: Requires conditioning with a minimum 20 bed volume rinse prior to first use.

Electrical

  • (No information available in extract)

Mechanical / hydraulic

  • Particle Size: 16 to 50 US Mesh (297 - 1190 μm)
  • % < 50 mesh (300µm): < 1%
  • Minimum Sphericity: 93%
  • Uniformity Coefficient: 1.6
  • Reversible Swelling (Cl to OH): 12% to 15%
  • Capacity (meq/mL): 1.4
  • Moisture Retention: 36% to 45%
  • Shipping Weight: 43 - 45 lbs/ft³ (689 - 721 g/L)
  • Color: White to Yellow
  • Regenerability: Yes
  • Backwash Expansion Chart: See the official PDF for exact tabulated values.
  • Pressure Loss Chart: See the official PDF for exact tabulated values.

Regeneration

  • Regenerant Concentration (Hydroxide cycle): 2 to 6 percent NaOH
  • Regenerant Concentration (Salt cycle): 2 to 10 percent NaCl
  • Regenerant level: 4 to 10 lbs./cu.ft.
  • Regenerant flow rate: 0.25 to 1.0 gpm/cu.ft.
  • Regenerant contact time: >40 minutes
  • Displacement flow rate: Same as dilution water
  • Displacement volume: 10 to 15 gallons/cu.ft.
  • Rinse flow rate: Same as service flow
  • Rinse volume: 35 to 60 gallons/cu.ft.

Suggested Service Flow Rate

  • Service flow rate: 1 to 10 gpm/cu.ft.

Applications

  • Trace Contaminants (U, Cr, As, Se, F, ClO₄, ClO₃)
  • Chromate Removal
  • Potable water treatment for removal of contaminants such as nitrate, arsenate, chromate, uranium, etc.
  • Nitrate removal (in chloride cycle)

Certifications

  • WQA Gold Seal* (NSF/ANSI/CAN 61: Drinking Water System Components - Health Effects)
  • Kosher Certified
  • FDA Compliance** (Paragraph 21CFR173.25 of the Food Additives Regulations of the US FDA)

Packaging Options

  • 500 ml samples
  • 1 ft³ bags
  • 1 ft³ boxes
  • 1 ft³ drums
  • 7 ft³ drums
  • 42 ft³ supersacks

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.