Datasheet summary
SBG2 UPS
PDF datasheet mirror for SBG2 UPS (ResinTech). Verify with OEM before design.
Summary
Product Identification
- Product Name: SBG2-UPS
- Product Type: STRONG BASE ANION
- Polymer Matrix: Styrenic Gel
- Functional Group: Dimethylethanolamine
- Ionic Form: Chloride
- Physical Form: Spherical Beads
- Particle Size: 20 to 40 US Mesh (400 - 841 μm)
- Uniformity Coefficient: 1.25
- Resin Type: Type II Anion, Polystyrene Gel
Operating Limits
- Maximum Continuous Temperature: 170°F (77°C)
- Operating pH Range: 0 to 14 SU
- Maximum Pressure Loss: 20 psi
Feed Water
- Suggested Operating Conditions: Contact ResinTech Technical Support for operation outside these guidelines.
Product Water
- When used in chloride form for nitrate removal, product water pH may be reduced during the early part of the exhaustion cycle.
Electrical
- No electrical specifications found.
Mechanical / Hydraulic
- Minimum Bed Depth: 24 inches
- Backwash Expansion: 25 to 50 percent
- Service Flow Rate: 1 to 10 gpm/cu.ft.
Regeneration
- Regenerant Concentration:
- Hydroxide cycle: 2 to 6 percent NaOH
- Salt cycle: 2 to 10 percent NaCl
- Regenerant Level: 4 to 10 lbs./cu.ft.
- Regenerant Flow Rate: 0.25 to 1.0 gpm/cu.ft.
- Regenerant Contact Time: >40 minutes
- Displacement Flow Rate: Same as dilution water
- Displacement Volume: 10 to 15 gallons/cu.ft.
- Rinse Flow Rate: Same as service flow
- Rinse Volume: 35 to 60 gallons/cu.ft.
Typical Properties & Physical Characteristics
- Capacity: 1.4 meq/mL
- Moisture Retention: 40% to 53%
- Reversible Swelling (Cl to OH): 12% to 15%
- % < 50 mesh (300µm): < 0.5%
- Minimum Sphericity: 95%
- Shipping Weight: 43 - 45 lbs/ft³ (689 - 721 g/L)
- Color: White to Yellow
- Regenerability: Yes
- Uniform Particle Size: Yes
Applications
- Dealkalizer
- Demineralization
- Trace Contaminants (U, Cr, As, Se, F, ClO₄, ClO₃)
- Nitrate Removal
- Sulfate Removal
Packaging Options
- 500 ml samples
- 1 ft³ bags
- 1 ft³ boxes
- 1 ft³ drums
- 7 ft³ drums
- 42 ft³ supersacks
Disclaimer
This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)