Datasheet summary
WACMP NA
PDF datasheet mirror for WACMP NA (ResinTech). Verify with OEM before design.
Summary
Product identification
- Product Name: WACMP-Na
- Product Line: ResinTech
- Type: Weak Acid Cation (WAC)
- Polymer Matrix: Acrylic Macroporous
- Ionic Form: Sodium (Na)
- Functional Group: Carboxylic Acid
- Physical Form: Spherical Beads
Typical Properties & Physical Characteristics
- Particle Size: 16 to 50 US Mesh (297 - 1190 μm)
- Percent < 50 mesh (300µm): < 1%
- Minimum Sphericity: 90%
- Uniformity Coefficient: 1.7
- Reversible Swelling (H to Na): 50% to 60%
- Temperature Limit: 180°F (82°C)
- Capacity (meq/mL): 2.5
- Moisture Retention: 43% to 60% (H form)
- Shipping Weight: 47 - 49 lbs/ft³ (753 - 785 g/L)
- Color: White to Cream
- Regenerability: Yes
Applications
- Partial Hardness Removal
- Metal Removal
- High TDS softening
ResinTech WACMP-Na is a sodium form gel weak acid cation resin intended for use in high TDS softening and for metal removal in waste treatment applications.
Packaging Options
- 1 ft³ bags
- 1 ft³ boxes
- 1 ft³ drums
- 7 ft³ drums
- 42 ft³ supersacks
Suggested Operating Conditions
- Maximum Continuous Temperature (Sodium form): 180°F
- Minimum Bed Depth: 30 inches
- Backwash Expansion: 25 to 50 percent
- Minimum Operating pH: >5 SU
- Service Flow Rate: 1 to 5 gpm/cu.ft.
Regenerant - Hydrogen Cycle
- Concentration: 1 to 5 percent HCl or 0.7 to 8 percent H₂SO₄
- Level: Approx 120% of theoretical
- Flow Rate: 0.3 to 1.5 gpm/cu.ft.
- Contact Time: >30 minutes
- Displacement Flow Rate: Same as dilution water
- Displacement Volume: 10 to 15 gallons/cu.ft.
- Rinse Flow Rate: Same as service flow
- Rinse Volume: 35 to 60 gallons/cu.ft.
Backwash Expansion Chart
- Values for expansion at various flow rates and temperatures.
Pressure Loss Chart
- Values for pressure loss per foot of resin at various flow rates and temperatures.
Capacity Charts
- Hardness Removal: Capacity versus TDS (ppm as CaCO₃) for different flow rates.
- General Capacity: Capacity versus flow rate.