Datasheet summary
Amberjet 1200 Na
PDF datasheet mirror for Amberjet 1200 Na (Rohm & Haas). Verify with OEM before design.
Summary
Product identification
- Product Name: AMBERJET™ 1200 Na
- Product Type: Industrial Grade Strong Acid Cation Exchanger
- Matrix: Styrene divinylbenzene copolymer
- Functional group: Sulfonate
- Ionic form as shipped: Na⁺
Performance
Operating capacity and ionic leakage depend on water analysis, temperature, and regenerant level. Engineering data sheets (EDS 0355 A, 0356 A, 0359 A, 0360 A, 0366 A, and 0367 A) provide information for calculation.
Typical Properties
- Physical form: Amber spherical beads
- Total exchange capacity [1]: ≥ 2.00 eq/L (Na⁺ form)
- Moisture holding capacity [1]: 43 to 47% (Na⁺ form)
- Shipping weight: 850 g/L
- Specific gravity: 1.26 to 1.30 (Na⁺ form)
- Particle size:
- Uniformity coefficient [1]: ≤ 1.2
- Harmonic mean size: 620 ± 50 µm
- Fines content [1]: < 0.300 mm : 0.1% max
- Maximum reversible swelling: Na⁺ ⇌ H⁺ : 10%
[1] Contractual value
Suggested Operating Conditions
- Maximum operating temperature: 135°C
- Minimum bed depth: 800 mm
- Service flow rate: 5 to 50 BV*/h
- Maximum service velocity: 60 m/h
- Regeneration:
- Regenerant: NaCl, HCl, H₂SO₄
- Level (g/L): 50 to 240 (NaCl), 40 to 150 (HCl), 40 to 200 (H₂SO₄)
- Concentration (%): 10 (NaCl), 4 to 10 (HCl), 1 to 8 (H₂SO₄)
- Minimum contact time: 20 minutes
- Slow rinse: 2 BV at regeneration flow rate
- Fast rinse: 1 to 3 BV at service flow rate
* 1 BV (Bed Volume) = 1 m³ solution per m³ resin
Limits of Use
AMBERJET 1200 Na resin is suitable for industrial uses. For other specific applications (pharmaceutical, food processing, potable water), consult Rohm and Haas.
Hydraulic Characteristics
Bed expansion is shown as a function of backwash flow rate and water temperature (Figure 1). Pressure drop data is shown as a function of service flow rate and water temperature (Figure 2). Pressure drop data are valid at the start of the service run with clear water and a correctly classified bed.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)