Amberjet 1500 H

PDF datasheet mirror for Amberjet 1500 H (Rohm & Haas). Verify with OEM before design.

Summary

Product identification

AMBERJET™ 1500 H Industrial Grade Strong Acid Cation Exchanger Styrene divinylbenzene copolymer matrix Functional groups: Sulphonates Physical form: Dark amber beads Ionic form as shipped: H⁺

Operating limits

Maximum operation temperature: 135 °C Minimum bed depth: 800 mm Service flow rate (Linear Velocity): 10 to 120 BV*/h

Regeneration

Regenerant: HCl or H₂SO₄ Level (g/L): 80 to 200 (HCl), 125 to 250 (H₂SO₄) Concentration (%): 5 to 6 (HCl), 1.5 to 4 (H₂SO₄) Minimum contact time: 30 minutes Slow rinse: 2 BV at regeneration flow rate Fast rinse: 1 to 3 BV at service flow rate

* 1 BV (Bed Volume) = 1 m³ solution per m³ resin

Properties

Total exchange capacity: ³ 2.0 eq/L (H⁺ form) Moisture holding capacity: 45 to 51 % (H⁺ form) Specific gravity: 1.28 to 1.32 (Na⁺ form) Shipping weight: 820 g/L Uniformity coefficient: £ 1.20 Harmonic mean size: 650 ± 50 μm Fine contents (< 0.425 mm): 0.5 % max

Limits of Use

AMBERJET 1500 H resin is suitable for industrial uses. For pharmaceutical, food processing, or potable water applications, consult Rohm and Haas for resin selection and operating conditions.

Hydraulic Characteristics

Bed expansion and pressure drop data are presented graphically in Figures 1 and 2 respectively. These figures show performance as a function of backwash/service flow rate and water temperature. Pressure drop data are valid at the start of the service run with clear water and a correctly classified bed.