Back to Rohm & Haas
Rohm & Haas logo

Datasheet summary

Amberlite 252 Na

PDF datasheet mirror for Amberlite 252 Na (Rohm & Haas). Verify with OEM before design.

Summary

Product identification

AMBERLITE™ 252 Na is an industrial grade strong acid cation exchanger. It is a macroporous cation exchange resin based on sulfonated cross-linked polystyrene with a moderate degree of crosslinking.

Properties

  • Physical form: Light grey spherical beads
  • Matrix: Styrene divinylbenzene copolymer
  • Functional group: Sulfonate
  • Ionic form as shipped: Na⁺
  • Total exchange capacity [1]: ≥ 1.80 eq/L (Na⁺ form)
  • Moisture holding capacity [1]: 47 - 54 % (Na⁺ form)
  • Shipping weight: 810 g/L
  • Specific gravity: 1.20 to 1.24 (Na⁺ form)
  • Particle size:
    • Uniformity coefficient: ≤ 1.8
    • Harmonic mean size: 0.590 – 0.840 mm
    • < 0.300 mm [1]: 1.0 % max

[1] Contractual value. Test methods are available on request.

Suggested operating conditions

  • Maximum operating temperature: 135 °C
  • Minimum bed depth: 700 mm
  • Service flow rate: 5 to 170 BV/h or 5 to 120 m/h

Regeneration

  • Regenerant: NaCl, HCl, H₂SO₄
  • Level (g/L):
    • NaCl: 80 to 400
    • HCl: 45 to 150
    • H₂SO₄: 50 to 200
  • Concentration (%):
    • NaCl: 10
    • HCl: 4 to 10
    • H₂SO₄: 1 to 5
  • Minimum contact time: 30 minutes
  • Rinse:
    • Slow rinse: 2 BV at regeneration flow rate
    • Fast rinse: 2 to 4 BV at service flow rate

* 1 BV (Bed Volume) = 1 m³ solution per m³ resin

Hydraulic characteristics

Figure 1 shows bed expansion as a function of backwash flow rate and water temperature. Figure 2 shows pressure drop data as a function of service flow rate and water temperature. Pressure drop data are valid at the start of the service run with clear water and a correctly classified bed.

  • Bed expansion: See Figure 1 in the official PDF.
  • Pressure drop: See Figure 2 in the official PDF.

Limits of use

AMBERLITE 252 Na resin is suitable for industrial uses. For other specific applications such as pharmaceutical, food processing or potable water applications, it is recommended to seek advice from Rohm and Haas.


Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.