Back to Rohm & Haas
Rohm & Haas logo

Datasheet summary

Amberlite IR122 Na

PDF datasheet mirror for Amberlite IR122 Na (Rohm & Haas). Verify with OEM before design.

Summary

Product identification

  • Product Name: AMBERLITE® IR122 Na
  • Description: Strong Acid Cation Exchanger. Premium quality, gel type, synthetic, high-capacity cation exchange resin of the sulfonated polystyrene type, supplied as small, insoluble beads in the sodium form.

Properties

  • Matrix: Styrene divinylbenzene copolymer
  • Functional Groups: Sulfonic Acid
  • Physical Form: Amber beads
  • Ionic Form, as shipped: Sodium
  • Total Exchange Capacity: 2.1 meq/ml minimum (Na⁺ form)
  • Moisture Holding Capacity: 38 to 44% (Na⁺ form)
  • Shipping Weight: 54 lbs/ft³
  • Harmonic mean size: 0.60 to 0.70 mm
  • Uniformity coefficient: 1.7 maximum
  • Screen Grading (wet): 16 to 50 mesh (US Std Screens)
  • Screen Analysis:
    • 5% maximum on 16 mesh (US Std Screens)
    • 1% maximum through 50 mesh (US Std Screens)
  • Maximum Reversible Swelling: Na⁺ → H⁺: approximately 10%

Suggested Operating Conditions

  • pH range: 0 to 14
  • Maximum operating temperature: 250 °F
  • Minimum bed depth: 24 inches
  • Service flow rate: 2 gpm/ft³
  • Minimum contact time: 30 minutes

Regenerants (100% basis)

RegenerantFlow Rate (gpm/ft³)Concentration (%)Level (lbs/ft³)
HCl0.3 to 0.754 to 102 to 8
H₂SO₄0.5 to 1.01 to 55 to 15
NaCl0.5 to 1.0105 to 25
  • Rinse flow rate: 1 gpm/ft³ initially, then 1.5 gal/ft³
  • Rinse Requirements: 25 to 75 gal/ft³

Hydraulic Characteristics

Pressure drop and bed expansion data are presented graphically in Figures 1 and 2, respectively. These figures show data as a function of service flow rate, backwash flow rate, and water temperature. Pressure drop data are valid at the start of the service run with clear water and a correctly classified bed.

Limits of Use

AMBERLITE IR122 Na is suitable for industrial use. For specific applications such as pharmaceutical, food processing, or potable water, consult Rohm and Haas Company for resin selection and operating conditions.


Disclaimer: Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror