Datasheet summary
Amberlite IRA 404 Cl
PDF datasheet mirror for Amberlite IRA 404 Cl (Rohm & Haas). Verify with OEM before design.
Summary
Product identification
- Product Name: AMBERLITE® IRA404 CI
- Type: Industrial Grade Strong Acid Cation Exchanger, Strong Base Anion Exchange Resin
- Matrix: Styrene divinylbenzene copolymer
- Functional groups: Type 1 Quaternary amine
- Physical form: Clear yellow beads
- Ionic form as shipped: Chloride
Properties
- Total exchange capacity: 1.1 meq/ml minimum (Cl form)
- Moisture holding capacity: 56 % min (Cr form)
- Shipping weight: 44 lbs/ft³
- Particle size: 16 to 50 mesh (US Std Screens)
- Screen Grading (wet): 5% maximum on 16 mesh, 1% maximum thru 50 mesh
- Uniformity coefficient: 1.5 maximum
- Maximum Reversible Swelling: Cl ↔ OH⁻: approximately 20%
Suggested Operating Conditions
- pH range: 0 to 14
- Maximum operating temperature:
- 140°F (OH form)
- 170°F (CI form)
- Minimum bed depth: 24 inches minimum
- Service flow rate: 0.25 to 3 gpm/ft³
Regenerant (100% basis)
-
NaOH:
- Level: 2.5 to 12.5 lbs/ft³
- Concentration: 2 to 4 %
- Flow rate: 0.25 to 1.0 gpm/ft³
- Minimum contact time: 30 minutes
-
NaCl:
- Level: 5 to 19 lbs/ft³
- Concentration: 10 %
- Flow rate: 0.25 to 1.0 gpm/ft³
- Minimum contact time: 15 gal/ft³ at regeneration flow rate
-
Rinse:
- Slow rinse: 30 to 60 gal/ft³ at service flow rate
- Fast rinse: See the official PDF for exact tabulated values.
-
Note: For color removal applications, alkaline brine (10% NaCl + 2% NaOH) can also be used.
Applications
- Decolorization of organic aqueous solutions derived from natural products (e.g. cane sugar syrups) or from fermentation broths (e.g. antibiotics)
- Enzyme Immobilization
- Organic trap ("Scavenger"), to remove natural organic components from surface water
Hydraulic Characteristics
Figure 1 shows the pressure drop data for Amberlite IRA 404 Cl resin as a function of flow rate and water temperature. Pressure drop data are valid at the start of the service run with clean water and a correctly classified bed. Figure 2 shows the bed expansion of Amberlite IRA 404 Cl as a function of backwash flow rate and water temperature. See the official PDF for exact tabulated values.
Safe Handling Information
Material Safety Data Sheets (MSDS) are available for all Rohm and Haas products. Consult your suppliers for appropriate health and safety precautions before using them.
- Caution: Acidic and basic regenerant solutions are corrosive and should be handled to prevent eye and skin contact. Recognize the hazards of other organic solvents and control exposure.
- Nitric acid and other strong oxidizing agents can cause explosive reactions when mixed with ion exchange resins. Proper equipment design is necessary to prevent rapid pressure build-up if oxidizing agents are used. Consult knowledgeable sources before using strong oxidizing agents with ion exchange resins.
- Ion exchange resins, as produced, contain by-products from the manufacturing process. Users must determine the extent to which organic by-products must be removed and establish techniques to achieve the appropriate level of purity. Users must ensure compliance with all prudent safety standards and regulatory requirements.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.