Amberlite IRA67

PDF datasheet mirror for Amberlite IRA67 (Rohm & Haas). Verify with OEM before design.

Summary

Product identification

  • Product Name: AMBERLITE™ IRA67
  • Product Type: Industrial Grade Weak Base Anion Exchanger
  • Matrix: Crosslinked acrylic gel structure
  • Functional group: Tertiary amine
  • Ionic form as shipped: Free Base (FB)
  • Physical form: Translucent white spherical beads

Properties

  • Total exchange capacity: ≥ 1.60 eq/L (FB form) [1]
  • Moisture holding capacity: 56 to 64 % (FB form) [1]
  • Shipping weight: 700 g/L
  • Particle size:
    • Uniformity coefficient: ≤ 1.80 [1]
    • Harmonic mean size: 0.500 – 0.750 mm [1]
    • Less than 0.300 mm: 3.0 % max [1]
  • Reversible swelling: FB → Cl⁻ ≤ 30 %

[1] Contractual value

Suggested Operating Conditions

  • Maximum operating temperature: 60 °C
  • Minimum bed depth: 700 mm
  • Service flow rate: 5 to 40 BV*/h

Regeneration

  • Regenerant: NaOH
  • Level: 130 % of ionic load
  • Concentration: 2 to 4 %
  • Minimum contact time: 30 minutes
  • Slow rinse: 2 BV at regeneration flow rate
  • Fast rinse: 8 to 16 BV at 10 BV/h

*1 BV (Bed Volume) = 1 m³ solution per m³ resin

Performance

  • Operating capacity: Depends on water composition (CO₂ and SO₄ content), specific flow rate, and ionic load. Offers 15 to 30 % higher operating capacity than polystyrenic weak base resins.
  • Regeneration: Optimum regeneration with caustic soda equivalent to 120 to 140 % of the operating capacity is suggested.
  • Organic matter: Offers large reversible capacity for organic matter removal due to its aliphatic structure and flexible acrylic polymer structure.

Hydraulic Characteristics

  • Pressure drop: Approximately 18 kPa/m bed depth per 10 m/h at 15 °C.
  • Backwash: A flow rate of 4 m/h provides approximately 65 % bed expansion at 15 °C.

Limits of Uses

Suitable for industrial water treatment. For pharmaceutical, food processing, or potable water applications, consult Rohm and Haas for resin selection and operating conditions.